--- title: "1. Project design and application" slug: "1project-design-and-application" updated: 2026-08-24T06:02:35Z published: 2026-08-24T06:02:35Z canonical: "knowledge.akuvox.com/1project-design-and-application" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 1. Project design and application | **Application program** | **Max. number of communication objects** | **Max. number of group addresses** | **Max. number of association tables** | | --- | --- | --- | --- | | HyPanel HyPanel Lite HyPanel Pro | 1153 | 2600 | 2600 | ## Function description **General setting** Configure device information, system language, proximity sensor, UI style and mode preferences, screen settings including saver, off times and screen lock, and date/time settings, etc. In addition, enable configuration of the distribution display and mode type of environmental sensors for environmental data collection, detection, and device linkage. **Homepage** Set shortcuts on the function page for quick navigation to execution pages and device functional blocks. The homepage supports different layout displays to suit user preferences. **Multifunction page** Configure lighting, blind control, value send, scenes saving, HVAC control, temperature control, background music, RGB/W dimming, air quality monitoring, energy data monitoring, and voice command binding. **Lighting** Control switches and dimmers, offering absolute and relative dimming methods, and supporting single-color and dual-color dimmer types. **Blind control** Control curtains and devices with blind adjustment, supporting both roller and venetian blinds . **Value send** Send values of different data types. **Scene control** Press to run scenes; long press to save scenes, optionally disabled. **HVAC** Adjust room temperature based on the user's housing environment and preferences. It supports manual switching between cooling and heating, offers three-level fan speed control with automatic adjustment and operation modes including standby, comfort, energy-saving, and protection. Support both relative and absolute temperature settings, fan coil type selection, and two-point and proportional–integral(PI) control. **Air conditioner** Air conditioner control typically includes split infrared (for households) and centralized gateway systems. The split infrared control akin to an air conditioning remote. Commands from the central control panel are transmitted via an infrared module or controller on the bus to power on/off, and adjust temperature, mode, and fan speed of the air conditioner. The air conditioning gateway is applicable for controlling multi-split units such as central air conditioning systems, and requires the KNX bus to AC gateway for control. **Background music** Manage the background music player, enabling control over functions like power on/off, play/pause, previous track, next track, adjust volume, select play mode, and choose music source. **RGB/RGBW dimming** Dim RGB or RGBW LED lights using absolute dimming method. **Air Quality monitoring** Collect temperature, humidity, PM2.5, PM10, CO2, AQI, VOC, light intensity, and wind speed periodically and display them. Each page can display up to four data. **Floor heating** Support two-point and PI control for automated valve operation based on temperature differences, enabling scheduling of underfloor heating and scene configuration. Temperature adjustments are limited to the valid range, with safeguards against setting abnormal values. **Ventilation system** Support for three-speed fan adjustment, turning on/off the power, heat exchange switching, filter lifespan monitoring, timeout alerts, and filter replacement reset. Also, it offers automatic fan speed adjustment based on configured parameters. **Energy metering display** Display current, voltage, power, and energy consumption data, which can be obtained through other KNX-compatible devices, electric meters, or gateways. **Time function** Enable scheduled transmission of diverse data values, offering up to 16 timing channels. Additionally, the settings of the timing function can be associated with bus devices. **Event group** Calling a scene number triggers 8 output telegrams with each supporting a choice of three data types. A total of 8 event groups are available for configuration. **Logic function** Support 8 logical inputs operations including AND, OR, and XOR, supports gate processing forwarding for converting one input to a single or multiple outputs. Also, it supports threshold comparators and data type conversion. There are 8 configurable logical groups in total.