--- title: "3.3.1 Multifunction" slug: "331" updated: 2026-08-24T06:14:46Z published: 2026-08-24T06:14:46Z canonical: "knowledge.akuvox.com/331" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 3.3.1 Multifunction #### ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-tacs5zvg.png) **Switch** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-m3kpqbio.png) **Switch/Dimming** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-egtbnurw.png) **Value send** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-7pqu4hu4.png) **Open/Close blind** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-pqfirz69.png) **Roller blind function(without slat)** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-8q0gvfup.png) **Venetian Blind function(with slat)** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-s0satx4e.png) **Blind(open/close/stop)** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-z4ehgppr.png) **Blind(up/down/stop)** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-cvcqum11.png) **Scene control** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.1-image-bfpinutw.png) **Color Temperature Dimming** Figure 3.3.1 Communication Objects of Multifunction (Lighting/Blind/Scene/Value send) | **No.** | **Object function** | **Name** | **Type** | **Flags** | **DPT** | | --- | --- | --- | --- | --- | --- | | **1** | **Switch** | **Page x-Icon y** | **1bit** | **C, T** | **1.001 switch** | | This communication object is used to send on/off telegrams to the bus to control the on/off state of the light. - Telegram values 1: On 0: Off | | **3** | **Switch Status** | **Page x-Icon y** | **1bit** | **C,W,T,U** | **1.001 switch** | | This communication object is used to receive the on/off status responses from other bus devices, such as dimmers and switches. | | **6** | **Brightness dimming** | **Page x-Icon y** | **1byte** | **C,T** | **5.001 percentage(0..100%)** | | This communication object is used to send dimming telegrams to the bus, transmitting brightness values. - Range: 0 ... 100%. | | **7** | **Brightness Status** | **Page x-Icon y** | **1byte** | **C,W,T,U** | **5.001 percentage(0..100%)** | | This communication object is used to receive the brightness status responses from dimmers. - Range: 0 ... 100%. | | **8** | **Relative dimming** | **Page x-Icon y** | **4 bit** | **C,W,T** | **3.007 dimming control** | | This communication object is used to send relative dimming telegrams to the bus, including telegrams of dimming up/down/stopping dimming. | | **9** | **Send 1bit/2bit/4bit/** **1byte/2byte value** | **Page x-Icon y** | **1bit on/off** **2bit 0..3** **4bit 0..15** **1byte 0..255** **1byte 0..100%** **2byte -32768..32767** **2byte 0..65535** | **C,T** | **1.001 switch** **2.001 switch control** **3.007 dimming control** **5.010 counter pulses(0..255)** **5.001 percentage(0..100%)** **8.001 pulses difference** **7.001 pulses** | | This object sends preset output values based on defined parameters. If both long and short press actions are specified, only the output value of the short press action is transmitted. The object type and value range are determined by the data type set in the parameters. | | **10** | **Send 1bit/2bit/4bit/** **1byte/2byte value, long** | **Page x-Icon y** | **1bit on/off** **2bit 0..3** **4bit 0..15** **1byte 0..255** **1byte 0..100%** **2byte -32768..32767** **2byte 0..65535** | **C,T** | **1.001 switch** **2.001 switch control** **3.007 dimming control** **5.010 counter pulses(0..255)** **5.001 percentage(0..100%)** **8.001 pulses difference** **7.001 pulses** | | This communication object is visible when distinguishing between long and short press actions, and it is used to send the output value for long press actions. | | **13** | **Open/Close** | **Page x-Icon y** | **1bit** | **C,W, T** | **1.009 open/close** | | **14** | **Stop** | **Page x-Icon y** | **1bit** | **C, T** | **1.007 step** | | **15** | **Blind position/status** | **Page x-Icon y** | **1byte** | **C,W,T,U** | **5.001 percentage(0..100%)** | | Open/Close Blind: Used for opening/closing curtains. Object descriptions: Obj. 1: Send telegrams of control the opening/closing of curtains to the bus. - Telegram values 1: Close 0: Open Obj.2: Send telegrams of stopping the movement of curtains to the bus. - Telegram values 0/1: Stop Obj.3: Send telegrams of controlling the position of curtains to the bus or receiving curtain actuator responses regarding curtain position status from the bus. - Telegram values 0 ... 100% | | **17** | **Up/Down** | **Page x-Icon y** | **1bit** | **C,W, T** | **1.008 up/down** | | **18** | **Stop** | **Page x-Icon y** | **1bit** | **C, T** | **1.007 step** | | **19** | **Blind position/status** | **Page x-Icon y** | **1byte** | **C,W,T,U** | **5.001 percentage(0..100%)** | | Roller Blind (without slat): Applicable for roller blinds without slats. Object descriptions: Obj.1: Send telegrams of controlling the up and down of the roller blind to the bus. - Telegram values 1: Down 0: Up Obj.2 and Obj.3: Same as above. | | **21** | **Up/Down** | **Page x-Icon y** | **1bit** | **C, T** | **1.008 up/down** | | **22** | **Stop/Slat adj.** | **Page x-Icon y** | **1bit** | **C, T** | **1.007 step** | | **23** | **Blind position/status** | **Page x-Icon y** | **1byte** | **C,W,T,U** | **5.001 percentage(0..100%)** | | **24** | **Slat position/status** | **Page x-Icon y** | **1byte** | **C,W,T,U** | **5.001 percentage(0..100%)** | | Venetian Blinds (with slats): Applicable for blinds with slats for angle adjustment. Object descriptions: Obj. 1 and Obj. 3: Same as above. Obj. 2: Send telegrams of stopping the movement of blinds or adjusting the slat angle to the bus. - Telegram values 1: Stop/Downward angle 0: Stop/Upward angle Obj. 4: Send telegrams of adjusting the angle of the slats to the bus or receiving responses regarding the slat angle status from the bus. - Telegram values 0 ... 100% | | **25** | **Open/Close** | **Page x-Icon y** | **1bit** | **C,W, T** | **1.009 open/close** | | **26** | **Stop** | **Page x-Icon y** | **1bit** | **C, T** | **1.007 step** | | Blind (open/close/stop): Applicable for opening and closing curtains. Object descriptions: Obj. 1: Send telegrams of opening/closing the curtains to the bus. - Telegram values 1: Close 0: Open Obj. 2: Send telegrams of stopping the movement of curtains to the bus. - Telegram values 0/1: Stop | | **29** | **Up/Down** | **Page x-Icon y** | **1bit** | **C, T** | **1.008 up/down** | | **30** | **Stop** | **Page x-Icon y** | **1bit** | **C, T** | **1.007 step** | | Blind (up/down/stop): Applicable for roller blinds. Object descriptions: Obj.1: Send telegrams of opening/closing the roller blinds to the bus. - Telegram values 1: Up 0: Down Obj. 2: Same as above. | | **33** | **Recall/storage scene No.** | **Page x-Icon y** | **1byte** | **C, T** | **18.001 scene control** | | This communication object is used to send telegrams of scene recall or scene storage. When the highest bit is 1, it indicates scene storage, and when the highest bit is 0, it indicates scene recall. | | **1202** | **Color Temperature** | **Page x-Icon y** | **2bytes** | **C,W,T,U** | **7.600 absolute colour temperature(K)** | | This communication object is used to send dimming color temperature telegrams which is the actual color temperature value to the bus. The telegram limit is set by specific parameters. | | **1203** | **Color Temperature,status** | **Page x-Icon y** | **2bytes** | **C,W,T,U** | **7.600 absolute colour temperature(K)** | | This communication object is used to receive the color temperature value status feedback from the dimmer, with the telegram limit determined by specific parameters. | Table 3.3.1 Multifunction basic function Communication Object Table