--- title: "3.3.6 Air Quality display" slug: "336" updated: 2026-08-24T06:15:15Z published: 2026-08-24T06:15:15Z canonical: "knowledge.akuvox.com/336" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 3.3.6 Air Quality display ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.6-image-a7biuho1.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.6-image-f1yugbq9.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.6-image-dsqsezdl.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.6-image-iv7i7ypj.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.6-image-sgyfl9ii.png) Figure 3.3.6 Air Quality display function Communication Object | **No.** | **Object function** | **Name** | **Type** | **Flags** | **DPT** | | --- | --- | --- | --- | --- | --- | | **161** | **AQI,In** | **Page x-Air Quality** | **2bytes** | **C,W,T,U** | **7.001 pulses** | | This object is used to receive inputs of AQI value and update the display with the value obtained from the bus. - Range: 0 ... 500 | | **162** | **PM2.5,In** | **Page x-Air Quality** | **2bytes** | **C,W,T,U** | **9.030 concentration(ug/m3)** **7.001 pulses** | | This object is used to receive inputs of PM2.5 value and update the display with the value obtained from the bus. The unit is micrograms per cubic meter (ug/m3). The data type of the object is determined by the parameter settings. - Range: 0 ... 999 | | **163** | **PM10,In** | **Page x-Air Quality** | **2bytes** | **C,W,T,U** | **9.030 concentration(ug/m3)** **7.001 pulses** | | This object is used to receive inputs of PM10 value and update the display with the value obtained from the bus. The unit is ug/m3. The data type of the object is determined by the parameter settings. - Range: 0 ... 999 | | **164** | **Temperature,In** | **Page x-Air Quality** | **2bytes** | **C,W,T,U** | **9.001 temperature(℃)** | | This object receives temperature measurement values from the temperature sensor on the bus. - Range: -40~40℃ | | **165** | **Humidity,In** | **Page x-Air Quality** | **2bytes** | **C,W,T,U** | **9.007 humidity(%)** | | This object is used to receive humidity measurement values from the humidity sensor on the bus. - Range: 0 ... 100%. | | **166** | **VOC,In** | **Page x-Air Quality** | **2bytes** | **C,W,T,U** | **9.008 parts/million(ppm)** **7.001 pulses** **9.030 concentration(ug/m3)** | | This communication object is used to receive VOC values sent from the VOC sensor on the bus. The unit is ug/m3. The data type of the object is determined by parameters. - Range: 0 ... 9.99 When the object data type is set to 7.001 pulses, it is scaled down by a factor of 1000 based on the data point type 7.001 pulses. For example, if the received value is 5000 (μg/m³), it would be displayed as 5.00 mg/m³. | | **167** | **CO2,In** | **Page x-Air Quality** | **2bytes** | **C,W,T,U** | **9.008 parts/million(ppm)** | | This object is used to receive CO2 (Carbon Dioxide) values sent from the CO2 sensor on the bus. The unit is ppm. - Range: 0 ... 4000 | | **168** | **Brightness,In** | **Page x-Air Quality** | **2bytes** | **C,W,T,U** | **7.013 brightness(lux)** **9.004 lux(Lux)** | | This object receives input brightness values from the bus and updates the display accordingly. The unit is lux. The data type of the object is determined by parameters. - Range: 0 ... 5000 | | **169** | **Windspeed** | **Page x-Air Quality** | **2bytes** | **C,W,T,U** | **9.005 speed(m/s)** | | This object receive the input of wind speed values from the bus and updates the display accordingly. The unit is m/s. - Range: 0 ... 50 | Table 3.3.6 Air Quality display function Communication Object Table