--- title: "3.3.7 Floor heating" slug: "337" updated: 2026-08-24T06:15:20Z published: 2026-08-24T06:15:20Z canonical: "knowledge.akuvox.com/337" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 3.3.7 Floor heating ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.7-image-puet97bc.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.7-image-sim77k9u.png) Figure 3.3.7 Floor heating function Communication Object | **No.** | **Object function** | **Name** | **Type** | **Flags** | **DPT** | | --- | --- | --- | --- | --- | --- | | **161** | **External temperature sensor, In** | **Page x-Floor heating** | **2bytes** | **C,W,T,U** | **9.001 temperature(℃)** | | This object is visible when the temperature reference is set to an external sensor. It is used to receive temperature measurement values sent from a temperature sensor on the bus. -Range: -50 ... 99.8°C | | **162** | **Power on/off, In/Out** | **Page x-Floor heating** | **1bit** | **C,W,T,U** | **1.001 switch** | | This object is used to send switch control telegrams for underfloor heating and receive control status feedback. -Telegram values 1: Underfloor heating control interface on, interface operable. 0: Underfloor heating control interface off, interface not operable. > [!NOTE] > **NOTE:** > > In the off state, all interface icons except for the timer and switch icons are non-operational. | | **163** | **Heating on/off, In/Out** | **Page x-Floor heating** | **1bit** | **C,W,T,U** | **1.001 switch** | | **163** | **Heating control value, Out** | **Page x-Floor heating** | **1byte** | **C,W,T,U** | **5.001 percentage (0..100%)** | | This object is used to send control values for floor heating, controlling the opening and closing of the underfloor heating valve. - Telegram values Heating on/off - 2-point control: On/off Heating PWM - use PI control: On/off Heating continuous control - use PI control: 0 ... 100% | | **164** | **Setpoint , In/Out** | **Page x-Floor heating** | **2bytes** | **C,W,T,U** | **9.001 temperature(℃)** | | This object is used to send temperature setting values to the bus and to receive feedback of the temperature setting values. - Range: 5 ... 40°C. | | **165** | **En./Dis. Timer, In** | **Page x-Floor heating** | **1bit** | **C,W** | **1.003 enable** | | This object is used to enable or disable the timer function of the floor heating system. The specific values are defined by parameters. | | **166** | **Scene, In** | **Page x-Floor heating** | **1byte** | **C,W** | **18.001 scene control** | | This object is used to control the scenes of the floor heating system. Parameter settings range from 1 to 64, correlating to actual telegram values from 0 to 63. | Table 3.3.7 Floor heating functional Communication Object Table