--- title: "3.3.9 Energy metering display" slug: "339" updated: 2026-08-24T06:15:36Z published: 2026-08-24T06:15:36Z canonical: "knowledge.akuvox.com/339" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 3.3.9 Energy metering display ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/3.3.9-image-xr4yz1x6.png) Figure 3.3.9 Energy metering display function Communication Object | **No.** | **Object function** | **Name** | **Type** | **Flags** | **DPT** | | --- | --- | --- | --- | --- | --- | | **161** | **Current in mA(DPT 7.012)** | **Page x-Energy Meter y** | **2bytes** | **C,W,T,U** | **7.012 current (mA)** | | This object is used to receive the current value from the bus and update it on the display. - Display range: 0 ~ 65535 mA, with a resolution of 1 mA. | | **162** | **Current in mA(DPT 9.021)** | **Page x-Energy Meter y** | **2bytes** | **C,W,T,U** | **9.021 current (mA)** | | This object is used to receive the current value from the bus and update it on the display. - Display range: -670760 ~ 670760 mA, with a resolution of 0.01 mA. | | **163** | **Current in A(DPT 14.019)** | **Page x-Energy Meter y** | **4bytes** | **C,W,T,U** | **14.019 electric current (A)** | | This object is used to receive the current value from the bus and update it on the display. - Display range: -99999999.9 ~ 99999999.9A , with a resolution of 0. 1A | | **164** | **Voltage in mV(DPT 9.020)** | **Page x-Energy Meter y** | **2bytes** | **C,W,T,U** | **9.020 voltage (mV)** | | This object is used to receive the voltage value from the bus and update it on the display. - Display range: -670760 ~ 670760mV, with a resolution of 0.01mV. | | **193** | **Voltage in V(DPT 14.027)** | **Page x-Energy Meter y** | **4bytes** | **C,W,T,U** | **14.027 electric potential (V)** | | This object is used to receive the voltage value from the bus and update it on the display. - Display range: -99999999.9 ~ 99999999.9V, with a resolution of 0. 1V. | | **194** | **Power in W(DPT 14.056)** | **Page x-Energy Meter y** | **4bytes** | **C,W,T,U** | **14.056 power (W)** | | This object is used to receive the power value from the bus and update it on the display. - Display range: -99999999.9 ~ 99999999.9W, with a resolution of 0. 1W. | | **195** | **Power in kW(DPT 9.024)** | **Page x-Energy Meter y** | **2bytes** | **C,W,T,U** | **9.024 power (kW)** | | This object is used to receive the power value from the bus and update it on the display. - Display range: -670760 ~ 670760kW, with a resolution of 0.01kW. | | **196** | **Active energy in Wh(DPT 13.010)** | **Page x-Energy Meter y** | **4bytes** | **C,W,T,U** | **13.010 active energy (Wh)** | | This object is used to receive the energy value from the bus and update it on the display. - Display range: -2147483648 ~ 2147483647Wh, with a resolution of 1Wh. | | **225** | **Active energy in kWh(DPT 13.013)** | **Page x-Energy Meter y** | **4bytes** | **C,W,T,U** | **13.013 active energy (kWh)** | | This object is used to receive the energy value from the bus and update it on the display. - Display range: -2147483648 ~ 2147483647kWh, with a resolution of 1kWh. | Table 3.3.9 Energy metering display function Communication Object Table