Figure 3.6.2 Logic function_Gate forwarding Communication Object
No. | Object function | Name | Type | Flags | DPT | |
585 | Gate value select | 1st /.../8th Logic | 1byte | C,W | 17.001 scene number | |
This object is used to select the scene forwarded by the logic gate. | ||||||
586/../589 | Input x | 1st /.../8th Logic | 1bit 4bit 1byte | C,W | 1.001 switch 3.007 dimming control 5.010 counter pulses(0..255) | |
This object is used to receive the value of logic gate Input x. | ||||||
590/../593 | Output x | 1st /.../8th Logic | 1bit 4bit 1byte | C,T | 1.001 switch 3.007 dimming control 5.010 counter pulses(0..255) | |
This object is used to output the value after logic gate forwarding. The output value is the same as the input value, but one input can be forwarded into one or more outputs, which are determined by parameters. | ||||||
Table 3.6.2 Logic function_Gate forwarding Communication Object Table