--- title: "4. Project Design and Application" slug: "4-4" updated: 2026-08-24T07:30:10Z published: 2026-08-24T07:30:10Z canonical: "knowledge.akuvox.com/4-4" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 4. Project Design and Application # | **Application** | **Max. Number of Communication Objects** | **Max. Number of Group Addresses** | **Max. Number of Security Group Addresses** | **Max. Number of Association Tables** | | --- | --- | --- | --- | --- | | K32 Multi-Function Panel | 1703 | 5500 | 5500 | 5500 | **Functional Description** **General Settings** This feature includes include device name configuration, system language selection, proximity sensor settings, temperature source selection, temperature unit selection, and screen saver time configuration. Temperature sensor calibration is also supported to ensure accurate environmental data collection and enable device interlocking based on temperature values. **Thermostat Function** The thermostat function is primarily used for room temperature control. It adapts heating and cooling control based on the actual living environment and user preferences. Features include: - Manual heating/cooling mode switching - Three-speed and auto fan control - Four operating modes: Standby, Comfort, Energy-saving, and Protection - Absolute and relative temperature setpoint adjustment - Support for fan coil control - Two-point control and PI control - Error code display **Air Conditioning Control** The supported control types of air conditioners are split-type infrared (for household use) AC and centralized gateways. The split-type (Infrared) air conditioners are similar to a standard remote controller. The panel sends control telegrams via a KNX infrared transmitter module or controller to operate the AC unit. Supported controls include: On/off, temperature, mode, and fan speed. Centralized systems are used for multi-split or central air-conditioning systems. Control is achieved through a KNX-to-AC gateway. Error code display is supported. **Underfloor heating control** Supports two-point and PI control methods, automatically controlling valve opening and closing based on temperature differences. Additional features include underfloor heating scene control, and adjustable temperature limits (avoid reverse or abnormal values). Error code display is supported. **Fresh Air System Control** Supports three-speed wind adjustment, power on/off, heat exchange switch, ilter lifetime monitoring, timeout alarm, and filter replacement reset, and automatic fan speed adjustment based on environmental parameters Error code display is supported. **Logical Function** Supports up to 8 logic channels, with each supporting up to 8 inputs and 1 logical output. Supported logic operations include AND, OR, XOR, gate forwarding, threshold comparison, format conversion, and gate calculation. **Scene Group Function** By calling a scene number, up to 8 output telegrams can be triggered. Each output supports three selectable data types. Up to 8 event groups can be configured. **Safety Function** Supports secure project download using FDSK. Projects can be protected with a password. If the password is forgotten, the device must be restored to factory settings and re-downloaded using the FDSK. **SN Download Function** After a full database download, the device can be bound to its Serial Number (SN). Once bound, the database can be downloaded directly via the SN without manually activating programming mode on the device.