--- title: "5.2 Parameter setting interface General Setting" slug: "52-parameter-setting-interface-general-setting" updated: 2026-08-21T06:26:48Z published: 2026-08-24T06:30:01Z canonical: "knowledge.akuvox.com/52-parameter-setting-interface-general-setting" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 5.2 Parameter setting interface General Setting ## 5.2.1 General Setting ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.2-parameter-setting-interface-general-setting-image-pmonj5eq.png) Figure 5.2.1 “General Setting” Interface - **Device name** Set the HyPanel’s name, which will be displayed on the HyPanel card. If left blank, the original name will be retained. The maximum length is 63 bytes. - **Interface Language** Specifies the display language for the panel. Options: English, Persian, German, Arabic, Spanish, French, Hebrew, Italian, Dutch, Polish, Portuguese, Turkish, Russian, Ukrainian, Simplified Chinese, Traditional Chinese, Japanese, Korean, Others. If your desired language is not listed, select “Others” and enter it in the Language name field. - **Language name** This field appears when Interface Language is set to **Others**. Enter the desired language from those supported by HyPanel. > [!NOTE] > **NOTE:** > > If the entered language is not supported by HyPanel, the previously downloaded will be displayed by default. - **Send cycle of “In operation”telegram [1...240s, 0 = inactive]** Set the time interval when this device cycle sends telegrams through the bus to indicate this module in normal operation. - When set to “0”, the object “In operation” will not send any telegram. - When set to a non-zero value, the object “In operation” will send a telegram with logic “1” to the bus at the configured interval. Options: 0 ~ 240s, 0=inactive. To reduce bus load, choose the longest acceptable interval based on actual requirements. - **Date and Time can be changed via bus** Determines whether the date and time displayed on the HyPanel can be modified via the bus. Options: - No: Cannot be modified via bus. The panel sends the current date and time to the bus every full hour. - Yes: Date/time can be modified via bus. When enabled, the "Date" and "Time" objects become visible. Configure them as needed. - **Display T&H resource** Specifies the source of temperature and humidity data displayed on the panel. Options: - Internal Sensor: Use the panel’s built-in temperature and humidity sensor. - External Sensor: Use an external temperature and humidity sensor. - **Temperature display units** Specifies the unit for displaying temperature on the panel. Options: - Celsius (℃) - Fahrenheit (℉) - **Screen brightness resource** Set the light sensor source of the HyPanel. Options: - Internal Sensor: Use the panel’s built-in light sensor. - External Sensor: Use an external light sensor. - **Sent brightness value to bus** This parameter is available when Screen Brightness Resource is set to Internal Sensor. It determines whether the panel sends its brightness value to the bus. Options: - No: Do not send brightness value. - Yes: Send brightness value. When selected, the “Screen backlight brightness” object becomes visible, and brightness changes will be reported to the bus. - **Automatic Brightness Control** Determines whether the panel automatically adjusts screen brightness. Options: - No: Disabled. - Yes: Enabled. When selected, HyPanel’s brightness will be automatically adjusted based on the current ambient light level. - **Screen Saver Times** Specifies the time interval before the HyPanel enters screensaver mode. Options: - 15s - 30s - 1min - 5mins - 10mins - 30mins - 1hr ## 5.2.2 Proximity Setting The Proximity Setting interface, as shown in Figure 2.2.2, configures the proximity sensing function. You can specify the proximity sensor source, detection distance, telegrams to be sent when a person approaches or leaves the sensing area, and the delay time for sending these telegrams. When the built-in sensor detects a person, it corresponds to “approaching”; when no presence is detected, it corresponds to “leaving”. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.2-parameter-setting-interface-general-setting-image-skokctog.png) Figure 5.2.2 “Proximity Setting” Interface - **Proximity** Sets whether to enable the proximity sensing function. Options: - Disable: Disables the proximity sensing function. The “Proximity sensor resource” setting will not be displayed. - Enable: Enables the proximity sensing function. When selected, the HyPanel will automatically wake up based on the selected sensor source. - **Proximity sensor resource** Displayed only when “Internal Sensor” is selected as the proximity sensor source. Used to select the sensor source for human presence detection. Options: - Internal Sensor: Use the panel's built-in sensor. The settings for “Proximity sensor distance” and “Object type of output value” will also be displayed. - External sensor: Use an external sensor. The settings for “Proximity sensor resource” and “Object type of output value” will not be displayed. - **Proximity sensor distance** Displayed only when “Internal Sensor” is selected as the proximity sensor source. Used to set the detection distance of the built-in sensor. Options: - Short distance: Detect presence within 50 cm. - Long distance: Detect presence within 100 cm. - **Object type of output value** Displayed only when “Internal Sensor” is selected. Used to define the data type of the telegrams sent to the bus when a person enters or leaves the sensing area. Options: - 1bit[On/Off] - 1byte[scene control] - 1byte[0..255] - 1byte[0..100%] - **Reaction for approaching/leaving** Sets whether a telegram should be sent when a person enters or leaves the sensing area. Options: - No action - Send a value: When selected, the following parameters become available: - Output value [On/Off] - Output scene NO. [1..64] - Output value [0..255] - Output value [0..100%] These parameters determine the telegram values sent to the bus. The valid range depends on the selected data type. - **Delay time for sending[0..255]** Sets the delay time before sending a telegram. Options: 0 ~ 255 > [!NOTE] > **NOTE:** > > If a leaving event is detected during the delay time set for an approaching telegram, the approaching telegram will be ignored. Telegrams are only sent when the proximity status changes. ## 5.2.3 Internal Temperature Setting The Internal Temperature Setting interface, as shown in Figure 5.2.3, configures parameters related to the built-in temperature sensor. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.2-parameter-setting-interface-general-setting-image-8dqbe264.png) Figure 5.2.3 “Internal Temperature Setting” Interface The following parameters allow you to configure the filter type, calibration offset, sending conditions, and cyclic sending interval for the internal temperature sensor. - **Filter type** Specifies how many measurements are averaged before sending the value to the bus. Options: - Low: Sends the average of 4 temperature readings. - Average: Sends the average of 16 temperature readings. - High: Sends the average of 64 temperature readings. - **Temperature offset** Applies a correction value to the measured temperature so it better reflects the ambient temperature. This adjustment only affects the value sent via telegram and does not impact the panel display. Options: -5℃~5℃ - **Minimum change of value to send[K] (0 means no value sent on change)** Defines the minimum temperature change that will trigger the sending of a new value to the bus. Options: 0...5 (0 disables value sending on change). - **Send actual Humi. when change by[1..20]** Sets the change threshold for humidity values to trigger sending the updated value to the bus. Options: 1 ~ 20 - **Cyclic sending interval** Specifies the time interval for periodically sending temperature values to the bus. Options: 0...120min This interval operates independently and starts timing upon programming completion or after a device reset. It is unaffected by value changes.