--- title: "5.3 Parameter setting interface “Button”" slug: "53-b" updated: 2026-08-18T06:48:24Z published: 2026-08-24T07:27:06Z canonical: "knowledge.akuvox.com/53-b" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 5.3 Parameter setting interface “Button” ## ## 5.3.1 “Button” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-spl9fh68.png) Figure 5.3.1 "Button" Interface - **Layout** Set the number of buttons on the K32 panel. Options: - 2 gang: 2 buttons - 3 gang: 3 buttons - 4 gang: 4 buttons - 6 gang: 6 buttons - 8 gang: 8 buttons The system will then generate corresponding thumbnails and text/icon configuration fields based on the selected button count. - **Long operation for button after** Set the time threshold for recognizing a long press. If a button is pressed longer than the set duration, it is treated as a long operation; otherwise, it is treated as a short press. - **Indicator** Select how the button label is displayed on the OLED screen. Options: - Text: Display a text label. - Icon: Display an icon. ***The following parameters appear when the “Text” is selected.*** **- Indicator text x** Set the displayed text, allowing up to 13 characters as input. > [!NOTE] > **NOTE:** > > The maximum display length depends on the layout and font size settings: > > - For 2, 3, or 4 gang layouts with Normal size: Up to 4 Chinese characters or 6 letters. > - For 2, 3, or 4 gang layouts with Large size: Up to 2 Chinese characters or 5 letters. > - For 6 or 8 gang layouts (Normal size only): Up to 2 Chinese characters or 3 letters. **- Size of font** Set the size of the text. Options: - Normal or Large for 2-4 gang layouts - Normal (default) for 6 and 8 gang layouts ***The following parameters appear when the “Icon” is selected.*** **- Indicator icon x** Select the icon to be displayed. Options: - Leave home - Dinner - Go home - Shade - AC - Lighting - Music - Sleep - Coffee - Floor heating - Gym, Reading - Scenario - **Function of button x** Set the function assigned to the button. Options: - Disable - Switch - Dimming - RGB lighting - RGBW lighting - colour control type - Value sender - Scene control - Shade - Shift register - Multiple operation - Delay mode ***The following sections provide detailed description for each button function.*** ## 5.3.2 “Switch” ## ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-mfb4u15z.png) Figure 5.3.2 "Switch" Interface - **Distinction between short and long operation** Set whether to distinguish between short and long button presses. Options: - No - Yes: The button differentiates based on the press duration. Only when the press time reaches the defined threshold will it be recognized as short or long, and the corresponding function will be executed. - **Reaction on short/press operation** - **Reaction on long/release operation** Define the action triggered during short or long press and release events. The object value is updated immediately upon confirmation. Options: - No reaction: No telegram is sent. - OFF: Send an “OFF” telegram. - ON: Send an “ON” telegram. - TOGGLE: Each operation alternates the switch state between ON and OFF. For example, if the previous telegram was ON, the next operation will send OFF, and the one after that will send ON again. The switch retains its last state and toggles accordingly with each activation. - **Number of objects** Visible when the long press/release action is not set to “No reaction”. Set whether short and long press actions share the same object or use separate ones. Options: - 1 - 2 - **Delay time** Set the delay before the telegram is sent. Options: 0...6500 - **LED indication colour** Set the LED indication state when the button has a switch function. Options: - Disable - Indicate Key switch: LED indicates based on the telegrams sent by the button。 > [!NOTE] > **NOTE:** > > This “Indicate Key switch” option is only available when the button function is switch or dimming and the group object is set to 1. - Indicate external object : LED indicate based on an external object - Indicate button press: LED lights up when the button is pressed - Always on ***The following parameters appear when the “Indicate Key switch” is selected.*** **- Object value="0", the color of LED** **- Object value="1", the color of LED** Set the LED color when the button sends a 0/1 telegram. Options: - Red - Green - Blue - White - Yellow - Cyan - Magenta - Orange - Cyan blue - Customized colour 1 - Customized colour 2 - Customized colour 3 - Customized colour 4 - Customized colour 5 ***The following parameters appear when the “Indicate external object” is selected.*** **- External object data types** Set the object type of the external object. Options: - 1bit - 1byte > [!NOTE] > **NOTE:** > > At startup, the device sends a read request. LED status reflects the reply; no LED change if no response is received. *When “1bit” is selected, the following parameters appear.* **- Object value="0", the color of LED** **- Object value="1", the color of LED** These parameters set the LED colour based on the 1bit value from the bus. Options: - Red - Green - Blue - White - Yellow - Cyan - Magenta - Orange - Cyan blue - Customized colour 1 - Customized colour 2 - Customized colour 3 - Customized colour 4 - Customized colour 5 *When “1byte” is selected, the following parameters appear.* **- Threshold value is** Set the threshold value. Options: 1~255 **- If object valuethreshold value, the color of LED** Set the LED color based on how the input value compares to the threshold. Available colors are the same as those listed for the 1bit option. ***The following parameters appear when the “Indicate button press” is selected.*** **- When press the button, the indication of LED** Set the LED indicator status when pressing the button. Options: - On - Flashing *When “On” is selected, the following parameters are visible.* **- On duration time is** Set how long the LED stays on. Options: - 500ms - 1s - 2s - 3s *When “Flashing” is selected, the following parameters are visible.* **- Flashing period time is** Set the LED flashing cycle. Options: - 0.4s - 0.8s - ... - 2.0s **- Normal indication is** Set the LED status after flashing. Options: - OFF - ON ***The following parameters appear when the “Indicate button press” or “Always on” is selected.*** **- LED indication colour** Set the LED indication colour. Options: - Red - Green - Blue - White - Yellow - Cyan - Magenta - Orange - Cyan blue - Customized colour 1 - Customized colour 2 - Customized colour 3 - Customized colour 4 - Customized colour 5 In the following sections, repeated LED settings will not be redefined due to similar usage. ## 5.3.3 “Dimming” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-bjenidzr.png) Figure 5.3.3 "Dimming" Interface - **Reaction on short operation** Set the switch value sent on a short operation. Options: - No reaction: No telegram sent. - OFF: Send “Off” telegram. - ON: Send “On” telegram. - TOGGLE: Toggle between “On” and “Off” on each operation. - **Reaction on long operation** Set the dimming value sent on a long operation. It sends a dimming telegram (brighter or darker), and stops dimming upon release. Options: - No reaction: No telegram sent. - Brighter: Send “Brighter” telegram. - Darker: Send “Darker” telegram. - Brighter/Darker: Alternate between “Brighter” and “Darker” on each operation. > [!NOTE] > **NOTE:** > > If either the switch or dimming parameter uses TOGGLE, they interact. For instance, if the switch is ON, the next dimming action darkens the light; if OFF, it brightens. - **Delay time** Set the delay before sending the telegram. Options: 0~6500 > [!NOTE] > **NOTE:** > > The delay time applies only to short presses. - **Dimming mode** This parameter appears when the parameter Reaction on long operation is not set to “No reaction”. It defines how dimming telegrams are sent. Options: - Start-stop dimming: Send a brighten/dim telegram when dimming starts, and a stop telegram when dimming ends. No cyclic telegrams are sent. - Step dimming: Send dimming telegrams cyclically. A stop telegram is sent when dimming ends. **- Step size** This parameter is visible when “Step dimming” is selected. It sets the brightness change (percentage) for a cyclic telegram. Options: - 100% - 50% - ... - 1.56% **- Interval of tele. cyclic send [0..25,0=send once]*0.1s** This parameter is visible when “Step dimming” is selected. It sets the time between cyclic telegrams. Options: 0~25 (0=Send only once) ### ## 5.3.4 “RGB lighting” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-ffjsfajo.png) Figure 5.3.4 "RGB lighting" Interface - **Object data type of absolute brightness** Set the data type for absolute brightness. Options: - 1*3byte: Control RGB lighting via a single 3-byte object. - 3*1byt: Control RGB lighting via three 1-byte objects. - **Reaction on short operation** - **Reaction on long operation** Set behavior for short or long presses. Options: - No reaction - OFF - ON - TOGGLE - Absolute value **- RGB value** This parameter is visible when “Absolute value” is selected. It sets the RGB value. Options: #000000~#FFFFFF ## 5.3.5 “RGBW lighting” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-oq2et0bd.png) Figure 5.3.5 "RGBW lighting" Interface - **Object data type of absolute brightness** Set the data type for absolute brightness. Options: - 1*6byte: Control RGBW lighting via a single 6-byte object. - 4*1byte: Control RGBW lighting via four 1-byte objects. - **Reaction on short operation** - **Reaction on long operation** Set behavior for short/long operation. Options: - No reaction - OFF - ON - TOGGLE - Absolute value **- White value** This parameter is visible when “Absolute value” is selected. It sets the white value. Options: 0~255 **- RGB value** This parameter is visible when “Absolute value” is selected. It sets the RGB value. Options: #000000~#FFFFFF ### ## 5.3.6 “Colour temperature control” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-s75b1do1.png) Figure 5.3.6 "Color temperature control" Interface - **Reaction on short operation** - **Reaction on long operation** Set behavior for short/long operation. Options: - No reaction - OFF - ON - TOGGLE - Absolute value **- Send brightness value** This parameter is visible when “Absolute value” is selected. It sets the brightness value. Options: 0~100 **- Send colour temperature value** This parameter is visible when “Absolute value” is selected. It sets the colour temperature value. Options: 0~10000 ### ## 5.3.7 “Value sender” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-qaezq5ve.png) Figure 5.3.7 "Value sender" Interface - **Delay time** Set the delay before sending telegrams. Options: 0~6500 - **Datatype of object during a short press** - **Datatype of object during a long press** Select the data type for telegrams sent on short or long presses. Options: - No reaction - 1bit value[ON/OFF] - 2bit value[0..3] - 4bit value[0..15] - 1byte signed value[-128..127] - 1byte unsigned value[0..255] - 1byte percentage[0-100%] - 2byte signed value[-32768..32767] - 2byte unsigned value[0..65535] - 2byte float value - 4byte signed value - 4byte unsigned value - 4byte float value - 14byte string **- Reaction to short operation** **- Reaction to long operation** These parameters are visible when the data type is not set to “No reaction”. - If 1-bit (ON/OFF) is selected: Options: - none - off - on - toggle - For other types. Value ranges depend on the previously selected data type. Options: - none - send value 1 - send value 2 - send value 1 <-> send value 2 ### ## 5.3.8 “Scene control” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-nk5qt871.png) Figure 5.3.8 "Scene control" Interface - **Reaction on short operation** - **Reaction on long operation** Set whether the press recalls or stores a scene. Options: - No reaction - Recall scene - Store scene **- 8 bit scene number** Visible when reaction is not “No reaction”. Select the scene number. Options: Scene NO.1 ~ 64 (Telegram values: 0~63) **- Number of objects** Visible when “Reaction on long operation” is not “No reaction”. Set whether short and long presses use a shared or separate object. Options: 1/2 ## 5.3.9 “Shade” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-exujlk1b.png) Figure 5.3.9 "Shade" Interface - **Reaction on short operation** - **Reaction on long operation** Set the action triggered by a short/long press. Options: - No reaction - Up - Down - Up/Down - Stop(Adjust Up) - Stop(Adjust Down) - Stop(Adjust Up/Down) **- Interval of tele. cyclic send [0..25,0=send once]*0.1s** Visible when a “Stop(Adjust…)” option is selected. It defines the interval between cyclic telegrams. Options: 0~25 (0 = Send only once) ## 5.3.10 “Shift register” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-pjhiwone.png) Figure 5.3.10.1 "Shift register_Shift by step value" Interface ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-gynuttyw.png) Figure 5.3.10.2 "Shift register_Shift without step value" Interface - **Shift type** Choose how values are shifted. Options: - Shift by step value: Set start and end values and the increment (direction from low to high) or decrement (direction from high to low) for each shift. - Shift without step value: Specify up to 10 fixed values to be sent sequentially with each shift operation. ***The following parameters appear when the “Shift by step value” is selected.*** **- Value begin with** Set the starting value. Options: 0~240 **- Value end with(must be larger than value begin with)** Set the ending value. Options: 1~250 > [!NOTE] > **NOTE:** > > The ending value must be greater than starting value. **- Step size** Set the step value to increment or decrement with each shift. Options: 0..240 ***The following parameters appear when the “Shift without step value” is selected.*** **- Object datatype** Set the data type for the shift object. Options: - 1 byte unsigned value - Scene number - HVAC mode **- Shift number** Set the number of shift values (maximum 10). Options: 0/1/2../10 **- Value x (x=1~10)** Set the value to be sent at each shift step. Valid range depends on the selected data type. Options: 0~255/Scene NO1~64/Comfort mode/Standby mode/Economy mode/Frost/heat protection - **Shift Direction** Set the shift direction. Options: - From lowest to highest and stop to the end - From highest to lowest and stop to the begin - From lowest to highest and cyclically - From highest to lowest and cyclically - **Reset function** Enable or disable the shift reset function. Options: - Disable - Enable by long operation: Resets the shift to the starting position via a long operation. ### ## 5.3.11 “Multiple operation” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-qs87wi11.png) Figure 5.3.11 "Multiple operation" Interface - **Object type for object x (x=1~4)** Set the data type to be sent during short/long operation. Options: - Disable - 1Bit On/Off - 1Bit Up/Down - 1Byte Recall Scene - 1Byte Store Scene - 1Byte Percentage - 1Byte Unsigned value - **Function of short operation** - **Function of long operation** Define the action for each operation: either “No reaction” or “Send Value” (the value is set in the next parameter). - **Value x... (x=1~2)** Visible when the object type is set to “1Byte Recall Scene”, “1Byte Store Scene”, “1Byte Percentage”, or “1Byte Unsigned value”. It specifies the value to be sent. The valid range depends on the selected data type in Object type for object x. ## 5.3.12 “Delay mode” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-uvf0erv3.png) Figure 5.3.12 "Delay mode" Interface - **Object type for short operation** - **Object type for long operation** Set the data type to be sent during short/long operation. Options: - Disable - 1Bit On/Off - 4Bit Dimming - 1Byte Unsigned value - **Send mode** Set how the value is sent. Options: - No action when operation,delay then send value1 - No action when operation,delay then send value2 - Send value1 when operation,delay then send value2 - Send value2 when operation,delay then send value1 - **Delay time [0..6500]s** Set the delay time. Options: 0~6500 - **Value x (x=1~2)** Set the values to be sent. The valid range depends on the selected data type. ## 5.3.13 “Customized color” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.3-b-image-vfj8ebt3.png) Figure 5.3.13 "Customized color" Interface - **Customized colour x (x=1~5)** **-RGB value** Customize the LED color. Users can customize up to 5 colors. Options: #000000~#FFFFFF