--- title: "5.4 Parameter Window ”ECG/Group Template setting”" slug: "54-et" updated: 2026-08-19T02:23:01Z published: 2026-08-24T07:58:29Z canonical: "knowledge.akuvox.com/54-et" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 5.4 Parameter Window ”ECG/Group Template setting” ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.4-et-image-ghi6uw97.png) Fig.5.4 “ECG/Group Template setting” Interface - **Parameter “Number of templates”** This parameter sets the number of parameter-setting templates for ECG and group operations, with a maximum of 8 templates. ### ## 5.4.1 Parameter Window “Template X(X=1~8)” Figure 5.4.1 shows the “Template X” interface, where group and ECG control action behaviors are configured. A total of 8 templates are available. If the group and ECG control actions are set to follow the ECG configuration, the action behaviors will be determined by the DCA tool settings. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-3K7Q8MLK.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-2QKDIHFL.png) Fig.5.4.1 “Template X”(X=1~8) Interface - **Parameter “Description (max.30 char)”** This parameter is used to input the parameter setting templates name (up to 30 characters). - **Parameter “Switch on value”** This parameter defines the brightness value of "Switch on". Options: - 1% - 2% - ... - 100% - Last brightness value: The value of the brightness before the light is turned off. Defaults to 50% when uncertain. > [!WARNING] > **TIP:** > > For ECG/Group with separate Normal/Night modes, this parameter defines the switching value for Normal mode. If no distinction is made, this value applies to both modes. - **Parameter “Switch on value in night mode”** This parameter defines the brightness value of "Switch on" in night mode. Options: - Disable: No distinction between Normal and Night modes; the switch-on brightness remains the same as in Normal mode. - 1% - 2% - ... - 100% - Last brightness value: Restore the brightness level before the lights were last turned off. Defaults to 10% if the previous value is unavailable. - **Parameter “Fade time”** This parameter sets the fade time of the DALI driver adjust brightness, colour temperature, and colour. Options: - 0s - 0.7s - 1.0s - 1.4s - 2.0s - ... - 90.5s - **Parameter “Value on DALI power fail (DALI System Failure Level)”** This parameter sets the brightness level of the light when the DALI bus loses power. The value is stored in the ECG, which automatically applies it after power loss. Options: - 0% - 1% - 2% - ... - 100% - Unchange: Maintain the brightness level prior to DALI bus power loss; the light brightness remains the same. - **Parameter “Value on ECG power recovery (DALI Power On Level)”** This parameter defines the brightness value of the light after ECG power-on reset. This value will be saved in the ECG, and the ECG will output the brightness value when the ECG is powered on and reset. Options: - 0% - 1% - 2% - ... - 100% - Value before failure: Restore the brightness to the level before the ECG lost power. - **Parameter “Value on KNX bus voltage recovery and download ”** This parameter defines the brightness level of lights after KNX bus voltage recovery or after downloading parameters. Options: - 0% - 1% - 2% - ... - 100% - Unchange: The brightness remains at its current level. - Value before failure: Restore the brightness to the state before KNX bus voltage failure. > [!NOTE] > **NOTE:** > > To ensure correct restoration, the brightness must be stable for at least 2 seconds before the KNX bus failure or download. For downloads, the brightness value before the download will be applied. - **Parameter “Dimming time for switch on/off”** This parameter defines the dimming time of the light brightness. That is, the dimming time of the brightness from 0% to 100% or 100% to 0%. Options: 0...255s - **Parameter “Dimming time for brightness dimming”** This parameter sets the duration for dimming the brightness to a new level. Options: 0...255s - **Parameter “Dimming time for relative dimming”** This parameter defines the dimming time for relative dimming. Options: 1...255s - **Parameter “Minimum brightness value”** This parameter defines the minimum control brightness value of the light, which refers to the minimum brightness value controllable by the DALI Gateway for lights. Options: - 0% - 1% - 2% - ... - 49% - **Parameter “Maximum brightness value”** This parameter defines the maximum control brightness value of the light, which refers to the maximum brightness value controllable by the DALI Gateway for lights. Options: - 50% - 51% - 52% - ... - 100% > [!NOTE] > **NOTE:** > > Any control command with brightness is limited to the minimum and maximum brightness value output. - **Parameter “Allow switch off via relative dimming”** This parameter defines whether to allow the light to be switched off by relative dimming . Options: - No(To the Min.brightness): Not allowed, only dim down to minimum brightness. - Yes: When the brightness is dim down to the minimum brightness value, the light is turned off directly. - **Parameter “Absolute dimming value lower than the minimum value”** This parameter sets the behavior when the absolute dimming value lower than the minimum value. Options: - 0%=0%, otherwise=Minimum brightness value: Output at the minimum brightness value. if it is 0%, the light is turned off. - To be the minimum brightness value: Output at the minimum value, even if it is 0%. - To be 0%: Turn off the light. - **Parameter “Burn In function”** This parameter enables or disables the burn-in function. During burn-in, the light operates at maximum brightness, and the ECG or group cannot be controlled individually. If the gateway powers off during burn-in, the mode does not resume automatically; it must be restarted via an object. When burn-in ends normally (time completed or stopped via object), the device will either switch on/off or return to its previous brightness, depending on the settings, and individual control is restored.. > [!NOTE] > **NOTE:** > > During burn-in, colour can still be adjusted and can be triggered or stopped via the channel A/B burn-in object. **- Parameter “Burn In duration”** After the burn in function is enabled, this parameter is visible and is used to set the duration of the burn in phase of the DALI device. Options: 1...255h - **Parameter “Dimming curve ”** This parameter sets the dimming curve type that the DALI device operates on when this template is selected. Options: - Logarithmic(DALI) - Linear(KNX) For example, if the driver currently uses a logarithmic curve: Selecting Logarithmic requires no adjustment, and selecting Linear simulates a linear dimming effect through fitting. This function works similarly to the dimming curve setting in broadcast control. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/5.4-et-image-2n2g6vdi.png)