--- title: "Door Setting" slug: "door-setting-2" updated: 2026-06-04T08:17:12Z published: 2026-06-04T08:17:12Z canonical: "knowledge.akuvox.com/door-setting-2" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # Door Setting ## Door Configuration A095 has 8 built-in relays, which can be connected to electrical door locks for access controls. 4 of them are named door 1-4, and the others are auxiliary outputs. Set up doors on the **Access Control > Door** interface**.** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-BRWN6DYD.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-1BSYV0PN.png) - **Type**: Determine the interpretation of the door status: - **Default State**: A “Low” status in the Door Status field indicates that the door is closed, while “High” indicates that it is open. - **Invert State**: A “Low” status in the Door Status field indicates an open door, while “High” indicates a closed one. - **Action to Execute**: Send an email notification to the preconfigured [email address](https://knowledge.akuvox.com/docs/security-42#security-notification). - **Mode**: Specify the conditions for automatically resetting the door status. - **Monostable**: The door status resets automatically within the trigger delay time after activation. - **Bistable**: The door status resets upon trigger again. - **Trigger Delay(Sec):** Set the delay time before the door opens. For example, if set to 5 seconds, the door will not open until 5 seconds later when users use their credentials. - **Hold Delay(Sec):** Determine the door-opening time. For example, if set to 5 seconds, the door stays open for 5 seconds. - **Relock When Door Closed**: Specify whether the relay should be reset (door relocked) immediately when the door is physically closed. - If disabled(the default), the relay reset follows the configured **Hold Delay (Sec)**. The relay will remain active until the configured time expires, regardless of the door sensor status. - If enabled, the relay is reset immediately when the door sensor **Input** detects that the door is closed. The door will be relocked without waiting for the **Hold Delay** time to expire. - **Status**: Indicate the state of the door, which is normally opened and closed. By default, it shows low for Normally Closed(NC) and high for Normally Open(NO). - **Trigger AUX OUT**: A095 has four auxiliary outputs that can be connected to devices such as a smoke sensor to carry out preset actions like setting off alarms or turning on the light. They can be triggered with specific doors. - **Door Sensor**: Specify which input interface is connected to a door sensor. - **Break-in intrusion**: Enable this option for detecting whether the door is forcibly or illegally opened. Click [here](/v1/docs/set-up-break-in-intrusion-alert) to learn more information about this feature. - **Break-in intrusion Execute Action**: Set whether to send a message to the preconfigured [Email address](https://knowledge.akuvox.com/docs/security-42#security-notification) when the break-in intrusion happens. - **Break-in intrusion Trigger Door**: Specify the **AUX OUT** to be triggered by break-in intrusion. - **Access Method**: Check the method(s) to open the door. - **Interlock**: This feature limits the opening of other doors when one door is open. For example, enable Interlock for Doors 1, 2, and 4. When Door 1 is opened, Door 2 or 4 cannot be opened until Door 1 is closed. While Door 3 is not affected. - **Interlock Type**: Available when **Interlock** is enabled. Set how to determine the door is closed, by door reset or [REX(Request to Exit)](https://knowledge.akuvox.com/docs/access-methods#unlock-by-exit-button) reset. - **Unlock Method**: Available when **Interlock** is enabled. Specify the method that opens the door. The settings of the corresponding [Wiegand](https://knowledge.akuvox.com/docs/integration-with-third-party-devices) and [DPS(Door Position Switch)](/v1/docs/relay-setting-2#door-position-switch-configuration) will be overwritten. > [!NOTE] > Note > > Click [here](/v1/docs/configure-interlock-feature) to view the Interlock feature details. ## Auxiliary Output Configuration The 4 auxiliary outputs(AUX OUT) can be connected to door locks, sirens, or warning devices. Set them up on the **Access Control > Auxiliary Output** interface**.** ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-IQQIJQSS.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-QTOTQ3SH.png) - **Action Type**: Select the function of the AUX OUT. - **Disabled**: Disable the interface. - **Door**: It is connected to a door lock. Additional door-specific settings become available below. - **AUX OUT**: Control an external device such as a siren or indicator light. **Output Behavior** (For **Door** and **AUX OUT** action types) - **Mode**: Specify the conditions for automatically resetting the output status. - **Monostable**: The status resets automatically within the trigger delay time after activation. - **Bistable**: The status resets upon trigger again. - **Hold Delay(Sec):** Determine how long the output stays activated. For example, if set to 5 seconds, the output remains activated for 5 seconds before closing. - **Output Status**: Indicate the states of the output, which are normally opened and closed. By default, it shows low for Normally Closed(NC) and high for Normally Open(NO). - **Action to Execute**: Send an email notification to the preconfigured [email address](https://knowledge.akuvox.com/docs/security-42#security-notification). **Door Settings** (For **Door** action type) - **Type**: Determine the interpretation of the door status: - **Default State**: A “Low” status in the Door Status field indicates that the door is closed, while “High” indicates that it is open. - **Invert State**: A “Low” status in the Door Status field indicates an open door, while “High” indicates a closed one. - **Trigger Delay(Sec):** Set the delay time before the door opens. For example, if set to 5 seconds, the door will not open until 5 seconds later when users use their credentials. - **Trigger AUX OUT**: Set whether to trigger one of the other three AUX OUTs when this output is activated. - **Door Sensor**: If the output is bound to a door sensor, specify which input interface is connected to the door sensor. - **Break-in intrusion**: Enable this option for detecting whether the door is forcibly or illegally opened. Click [here](/v1/docs/set-up-break-in-intrusion-alert) to learn more information about this feature. - **Break-in intrusion Execute Action**: Set whether to send a message to the preconfigured [Email address](https://knowledge.akuvox.com/docs/security-42#security-notification) when the break-in intrusion event happens. - **Break-in intrusion Trigger Door**: Specify the **AUX OUT** to be triggered by a break-in intrusion. - **Access Method**: Check the method(s) to open the door. - **Interlock**: This feature limits the opening of other doors when one door is open. For example, enable Interlock for Doors 1, 2, and 4. When Door 1 is opened, Door 2 or 4 cannot be opened until Door 1 is closed. While Door 3 is not affected. - **Interlock Type**: Available when **Interlock** is enabled. Set how to determine the door is closed, by door reset, [DPS(Door Position Switch)](/v1/docs/relay-setting-2#door-position-switch-configuration), or [REX(Request to Exit)](https://knowledge.akuvox.com/docs/access-methods#unlock-by-exit-button) reset. - **Unlock Method**: Available when **Interlock** is enabled. Specify the method that opens the door. The settings of the corresponding [Wiegand](https://knowledge.akuvox.com/docs/integration-with-third-party-devices) and [DPS(Door Position Switch)](/v1/docs/relay-setting-2#door-position-switch-configuration) will be overwritten. > [!NOTE] > Note > > Click [here](/v1/docs/configure-interlock-feature) to view the Interlock feature details. ## Door Position Switch Configuration The device has 8 extra inputs. 4 of them can be connected to door position switches for detecting the open or closed status of doors. To set up DPS, go to the **Access Control > Door > DPS(Door Position Switch)** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-1T2TKBBE.png) - **Enabled**: Specify the input used. - **Trigger Option**: Set the input interface to trigger at a low or high electrical level. - **Alarm Door Opened**: This feature triggers an alarm when a door remains open longer than the configured duration. - **Timeout Alert(Sec)**: The number of seconds a door can remain open before the alarm is triggered. - **Reset Alarm When Door Closed**: Determine whether the door-open timeout alarm is automatically cleared when the door is closed. - If it is disabled(the default), when a timeout triggers the **Output** alarm, the alarm duration is determined by the **Hold Delay** configured for the Output, regardless of whether the door is closed. - If it is enabled, the **Output** alarm will be cleared automatically when the **Input** status is reset (for example, when the door is closed). In this case, the alarm stops immediately instead of waiting for the **Hold Delay** to expire. - **Action to Execute**: Set the desired actions that occur when this input interface is triggered. - **Email**: Send a message to the preconfigured [Email address](https://knowledge.akuvox.com/docs/security-42#security-notification). - **HTTP URL**: When triggered, the HTTP message can be captured and displayed in the corresponding packets. To utilize this feature, enable the HTTP server and enter the message content in the designated box below. The format is *http://HTTP server’s IP/Message content*. - **Trigger AUX OUT**: Specify an auxiliary output to be activated when the timeout alert is triggered. - **Close AUX OUT**: Specify an auxiliary output to be deactivated when the timeout alert is cleared. Please note that this feature does not work during the relay schedule time. - **Report to Server**: Set whether to report the alarm logs to ACMS or SmartPlus Cloud, where the device is deployed, when the timeout alert is triggered. - **Status**: Display the status of the input signal. ## Web Relay A web relay has a built-in web server and can be controlled via the Internet or a local network. The device can use a web relay to either control a local relay, or a remote relay somewhere else on the network. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-1702022071712.png) Click [here](https://knowledge.akuvox.com/docs/configure-web-relay-on-door-phone-web-interface) to view how to set up web relay. To set it up, go to the **Access Control > Web Relay** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-VSQ2XLDM.png) - **Type**: Determine the type of relay activated when employing door access methods for entry. - **Disabled**: Only activate the local relay. - **Web Relay**: Only activate the web relay. - **Both**: Activate both the local relay and web relay. Typically, the local relay is triggered first, followed by the web relay. - **IP Address**: The web relay IP address provided by the web relay manufacturer. - **Username**: The user name provided by the web relay manufacturer. - **Password**: The manufacturer-provided authentication key for the web relay. Authentication occurs via HTTP. Leaving the Password field blank indicates non-use of HTTP authentication. You can define the password using HTTP GET in the Web Relay Action field. - **Web Relay Action**: Configure the actions to be performed by the web relay upon triggering. Enter the manufacturer-provided URLs for various actions, with up to 50 commands. > [!NOTE] > Note > > If the URL includes full HTTP content (e.g., http://admin:admin@192.168.1.2/state.xml?relayState=2), it doesn't rely on the IP address that you entered above. However, if the URL is simpler (e.g., "state.xml?relayState=2"), the relay uses the entered IP address.