--- title: "Door-opening Configuration" slug: "door-unlock-configuration-18-1" updated: 2026-09-04T08:14:16Z published: 2026-09-04T08:14:16Z canonical: "knowledge.akuvox.com/door-unlock-configuration-18-1" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # Door-opening Configuration ## User-specific Access Methods The private PIN code, RF card, and Bluetooth setting should be assigned to a particular user for door opening. When adding a user, you can also customize settings such as defining the door access schedule to determine when the code is valid and specifying which relay to open. To add a user, go to **Directory > User** interface and Click **+Add**. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/图片-RX1NLVSP.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/图片-IOANC6ZA.png) - **User ID**: The unique identification number assigned to the user. - **Name**: The name of this user. ### Unlock by Private PIN Code The device can be connected to an external keypad. Users can open doors by entering their private PINs on the keypad. On the **Directory > User > +Add** interface, scroll to the **PIN** section. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/图片-9X6K9HI0.png) - **Code**: Set a 2-8 digit PIN code solely for the use of this user. Each user can only be assigned a single PIN code. ### Unlock by RF Card/Bkey On the **Directory > User > +Add** interface, scroll to the **RF Card** section. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-JXNGGPZA.png) - **Code**: The card code or Bkey code that the card reader reads. > [!NOTE] > Note: > > - Click [here](https://knowledge.akuvox.com/docs/open-the-door-via-bkey) to view the detailed steps of configuring Bkey. > - Each user can have a maximum of 5 cards added. > - The device allows to add 20,000 users. > - RF cards operating at 13.56 MHz and 125 KHz frequencies are compatible with the device for access. #### RF Card Code Format To integrate the RF card door access with the third-party intercom system, you need to match the RF card code format with the one used by the third-party system. To set it up, go to **Access Control > Card Setting > RFID** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-OK5I80PI.png) - **IC/ID Card Display Mode**: Set the card number format from the provided options. The default format in the device is 8HN. - **ID Card Reading Bytes**: Select the number of bytes read from the ID card, 3 bytes or 4 bytes. ### Unlock by License Plate Akuvox offers two main ways to identify vehicles and open gates. - Use [a third-party LPR(License Plate Recognition) camera](https://knowledge.akuvox.com/v1/docs/integration-with-milesight-lpr-camera-for-door-opening) to recognize the license plate of the vehicle. - Use the [Akuvox long-range card reader ACR-CPR12](https://knowledge.akuvox.com/v1/docs/akuvox-vehicle-access-control-configuration) to recognize the UHF card attached to the vehicle's windshield. To assign the license plate to a user, find the **License Plate** part on the **Directory > User > +Add** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-U92JT522.png) - **Add**: A user can have up to 5 license plates. - **Duration**: Enable/disable Long-term Vehicle. It is enabled by default. If disabled, specify when the vehicle can enter or exit the parking lot. ### Unlock by Bluetooth A03 supports opening the door via Bluetooth-enabled My MobileKey or SmartPlus App. Users can either open the door with the apps in their pockets or wave their phones towards the device as they get closer to the door. #### Unlock via My MobileKey On the **Directory > User > +Add** interface, scroll to the **BLE Setting** section. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-3OQK2FHF.png) - **Authentication Code**: Click **Generate** to generate a 6-digit verification code. You can set up the pairing valid time within which users need to finish the pairing. To set it up, go to **Access Control > BLE > BLE** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-9SELYI5I.png) > [!NOTE] > Note > > Click [here](https://knowledge.akuvox.com/v1/docs/open-the-door-via-my-mobilekey-app) to see the configuration steps. #### Unlock via SmartPlus App To open the door via the SmartPlus App, the device should be connected to the SmartPlus Cloud. To set up Bluetooth unlock, go to **Access Control > BLE > BLE** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-CMZDMQWH.png) - **Enable Hands Free Mode**: If enabled, users can gain door access hands-free. If disabled, users have to wave their hands near the device to open doors. - **RSSI Threshold**: Set the received signal strength. Higher values indicate stronger signal strength, making it easier to receive the Bluetooth signal. - **Bkey Trigger Signal**: There are three ranges that determine the Bkey trigger distance(1~5 meters). - **Unlock Interval For Same User(Sec)**: Set the time interval between consecutive Bluetooth door access attempts for the same user. - **Unlock Interval For Different User(Sec)**: Set the time interval between consecutive Bluetooth door access attempts for different users. > [!NOTE] > Note > > To learn about detailed configuration steps of different Bluetooth-based access methods, you can click the following articles. > > - [Unlock by Bluetooth via My MobileKey App](https://knowledge.akuvox.com/docs/open-the-door-via-my-mobilekey-app). > - [Unlock by Bluetooth via SmartPlus App](https://knowledge.akuvox.com/docs/open-the-door-via-bluetooth). > - [Open the Door via Bkey.](https://knowledge.akuvox.com/docs/open-the-door-via-bkey) #### Device Info Setting You can customize the device name and ID for convenient Bluetooth pairing. To set it up, go to **Access Control > BLE > Device Info Settings** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-DWRHAWLR.png) - **Device Name**: Limited to 1-63 numbers or characters. - **Device ID**: Limited to 1-12 numbers or characters. #### Movement Detection Setting This feature only works for Bluetooth-based door opening via the My Mobilekey App. When enabled, users cannot open the door without shaking their mobile phones. Enable the function on the **Access Control > BLE > Movement Detection** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-B2U5222R.png) ### Access Setting You can customize access settings, such as defining the door access schedule to determine when the code is valid and specifying which relay to open. On the **Directory > User > +Add** interface, scroll to the **Access Setting** section. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-P7VAXR9I.png) - **Relay**: Check the relay to be unlocked using the door opening methods assigned to the user. - **Security Relay**: Select the security relay that you’ve configured on the [Security Relay](https://knowledge.akuvox.com/docs/relay-settings-1#security-relay) interface. - **First Credential In:** This decides whether the user can keep the door open during the [scheduled time](https://knowledge.akuvox.com/docs/door-access-schedule-management-18-1#relay-schedule) after activating it. - **Lockdown Bypass**: This decides whether the user can open the door when the door is locked during the [scheduled time](https://knowledge.akuvox.com/docs/door-access-schedule-management-18-1#relay-schedule). - **Floor No.** : Specify the accessible floor(s) to the user via the [elevator](https://knowledge.akuvox.com/docs/integration-with-third-party-device-18-1#lift-control). - **Web Relay**: Specify the ID of web relay action commands that you’ve configured on the [Web Relay](https://knowledge.akuvox.com/docs/relay-settings-1#web-relay) interface. A default value of 0 indicates that the web relay will not be triggered. - **HTTP URL**: Specify the HTTP URL sent to another Akuvox device for door opening. You can add up to 10 commands. - **Schedule**: Grant the user access to open designated doors during preset periods by relocating the desired schedule(s) from the left box to the right one. Besides custom schedules, there are 2 default options: - **Always**: Allows door opening without limitations on door open counts during the valid period. - **Never**: Prohibits door opening. > [!WARNING] > Tip > > Here is an HTTP command URL example: > > ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-HBYXQ3K5.png) > [!NOTE] > Note > > The HTTP format for relay triggering varies depending on whether the door phone's high secure mode is enabled. Please refer to this how-to guide [Opening the Door via HTTP Command](https://knowledge.akuvox.com/docs/open-door-via-http-command) for more information. ### Import/Export User Data The device supports access control user data being shared among Akuvox devices through import and export. Click [here](https://knowledge.akuvox.com/docs/import-users-in-batch-to-door-phones) to view how to import and export user data between Akuvox devices. To set it up, go to the **Directory > User** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-NBA1DN67.png) > [!NOTE] > Note > > For the import file: > > - Format:.tgz/.xml, size: < 2.8MB (Each .xml file) > - Format:.csv, size: < 18MB > > The file is exported in the XML or CSV format. ## NFC and Felica Card Setting Set the device to support NFC and Felica cards on the device before they can be used. To set it up, go to **Access Control > Card Setting > Contactless Smart Card** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/图片-6EHYI4UB.png) - **Enabled**: Select NFC or Felica from the list. - **Felica Reading Format**: When Felica is selected, set the card reading format between 8 Bytes and 16 Bytes. The default is 16 Bytes. > [!NOTE] > Note > > The NFC feature is not available on iPhones. ## Mifare Card Encryption The device can encrypt Mifare cards for greater security. When this feature is enabled, it reads the data in the cards’ designated sectors and blocks, not the UID. To set it up, go to **Access Control > Card Setting > Mifare Card Encryption** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-XRQ4JS0C.png) - **Enabled**: The device supports Mifare Classic, Mifare Desfire, and Mifare Plus. - **Classic**: - **Sector/Block**: Specify the location where encrypted card data is stored. A Mifare card has 16 sectors (0 to 15), and each sector has 4 blocks (0 to 3). - **Block Key**: Set a password to access the data stored in the predefined sector/block. - **Key Type**: The authentication key type used to read the Mifare Classic card - **Data Offset**: The starting byte position from which card data is read. The default is 0. - **Data Length**: The number of valid data bytes to read from the card. The default is 4. - **Plus**: There are three choices. The device can read the encrypted data in SL1 and SL3. - **Block**: The block number where the encrypted data is located. - **SL3**: The key number within 32 bits. - **DESFire**: - **App ID**: A 6-digit hexadecimal number - **File ID**: The ID of the encrypted file of the app, which can be a number from 0 to 31. - **Crypto**: The encryption method, either AES or DES. - **Key**: The file key. - **Key Index**: The index number for the key, which can be a number from 0 to 11. - **Byte Order**: The byte reading order. The default is MSB. The device starts reading bytes after performing **Data Offset** and **Data Length**. - **MSB**: Most Significant Bit means the reading order is normal(from left to right). - **LSB**: Least Significant Bit means the reading order is reversed(from right to left). - **Data Offset**: Define from which byte position to start reading data, with a range of 0 to 43. The default is 0. - **Data Length**: Define the length of valid byte data, with a range of 1 to 8. The default is 4. ## Unlock by HTTP Command You can unlock the door remotely without approaching the device physically for door entry by typing in the created HTTP command (URL) on the web browser to trigger the relay when you are not available by the door for door entry. To set it up, go to **Access Control > Relay > Open Relay Via HTTP** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/图片-H7TOUUZ1.png) - **Username**: Set a username for authentication in HTTP command URLs. - **Password**: Set a password for authentication in HTTP command URLs. > [!WARNING] > Tip: > > Here is an HTTP command URL example for relay triggering. > > ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-22HOI78M(1).png) ## Unlock by Exit Button When users need to open the door from inside by pressing the Exit button, you need to set up the Input terminal that matches the Exit button to activate the relay for the door access. Click [here](https://knowledge.akuvox.com/docs/push-exit-button-connection-video) to watch the instruction video. To set it up, go to **Access Control > Input** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/图片-AN48BRJW.png) - **Enabled**: To use a specific input interface. - **Trigger Electrical Level**: Set the input interface to trigger at low or high electrical level. - **Action To Execute**: Set the desired actions that occur when the specific Input interface is triggered. - **Email**: Send a screenshot to the preconfigured [Email address](https://knowledge.akuvox.com/docs/security-35-1#email-notification). - **HTTP**: When triggered, the HTTP message can be captured and displayed in the corresponding packets. To utilize this feature, enable the HTTP server and enter the message content in the designated box below. - **HTTP URL**: Enter the HTTP message if selecting HTTP as the action to execute. The format is http://HTTP server’s IP/Message content. - **Action Delay**: Specify how many seconds to delay executing the preconfigured actions. - **Action Delay Mode**: - **Unconditional Execution**: The action will be carried out when the input is triggered. - **Execute If Input Still Triggered**: The action will be carried out when the input stays triggered. For example, if the door stays open after triggering input, an action such as an email will be sent to notify the receiver. - **Execute Relay**: Specify the relay to be triggered by the actions. - **Alarm Door Opened**: If enabled, when the door-opening time exceeds a limit, an alarm will be triggered. - **Door Opened Timeout**: The door-opening time limit. - **Door Opened Timeout**: Set the time limit for the door to stay open. - **Break-in Intrusion**: Activate an alarm when the door is forcibly or illegally opened. Only by checking off this option can the alarm be turned off once triggered. Click [here](https://knowledge.akuvox.com/docs/set-up-break-in-intrusion-alert) to learn more information about this feature. - **Door Status**: Display the status of the input signal.