F52-KNX-EU Flush Mounted Module

Prev Next

[F52-KNX-EU Flush Mounted Module Upgrade Package  (Click to download)]

Version: 0.0.27

NOTE:

The database will be erased after upgrading the flush mounted module.


Release Notes

Version: 0.0.27

Release Date: November 19, 2025

Optimizations

  1. Updated the burn-in duration to 4 hours.


Version: 0.0.26

Release Date: November 5, 2025

Fixed Bugs

  1. Fixed an issue where, after enabling KNX Secure, ETS downloads failed because the secure group address became linked to too many communication objects when associated with other secure devices in the project.


Version: 0.0.22

Release Date: July 28, 2025

New Features

  1. General Settings

    1. Support configuring the device name.

    2. Support selecting the device language.

    3. Support setting the interval for sending operating status telegrams (0 = Do not send).

    4. Support configuring bus time synchronization:

      • Yes: The device time can be modified via the KNX bus.

      • No: The device sends date and time to the bus at every full hour.

    5. Support selecting the temperature & humidity source: external or internal sensor.

    6. Support switching the temperature unit.

    7. Support selecting the light sensor source: external or internal light sensor.

    8. Support auto-brightness adjustment.

    9. Support configuring the screensaver timeout.

    10. Support Proximity function:

      • Select internal or external sensor as the detection source.

      • When using the internal sensor, detection distance is configurable.

      • When using the internal sensor, the telegram type and delay time are configurable.

    11. Support internal temperature sensor calibration.

  2. Advanced Settings

     a. Support configuring the flush mounted module capabilities, including Relay Output, IO Input, and NO Output

     b. Support enabling or disabling Home Page and Key Button features.

  3. Location

    1. Support configuring up to 10 floors.

    2. Support configuring up to 10 rooms per floor.

  4. Function

    1. Support up to 80 Function List pages:

      • Pages 1–40: Basic Functions only

      • Pages 41–80: Basic Functions or Advanced Functions

    2. Basic Function supports the following types:

      • Switch

      • Lighting

      • Relative dimming

      • Absolute dimming

      • Relative + absolute dimming

      • Brightness + color temperature

      • Shade position

      • Roller blind position

      • Venetian blind position and slat

      • Venetian curtain position and slat

      • Shade step/move

      • Roller blind step/move

      • Value sender

      • Scene control

      • External Device (KNX sensor)

      • External Device (Non-KNX sensor)

    3. Advanced Function supports the following types:

      • HVAC

      • Air conditioner

      • Audio control module

      • RGB color control

      • Air quality display

      • Floor heating

      • Ventilation system

      • Energy metering display

      • Advanced switch

  5. Home Page

    1. Support selecting the Home Page display type:

      • Small screen

      • Large screen (landscape)

      • Large screen (portrait)

    2. Support configuring up to 10 Home Page pages.

    3. Support assigning devices to each Home Page based on the selected display type.

  6. Key Button

    1. Support selecting the Key Button display type:

      • 2-key

      • 4-key

      • 6-key

      • Custom

    2. Support assigning devices to Key Buttons based on the selected type.

  7. Logic Function

    1. Support the following logic modes:

      • AND

      • OR

      • XOR

      • Gate forwarding

      • Threshold comparator

      • Format conversion

      • Gate calculation

  8. Event Group Function

    1. Support up to 8 Event Groups, each providing 8 outputs.

  9. KNX Secure

    1. Support enabling or disabling KNX Secure.

    NOTE:

    When KNX Secure is enabled, the device assigns new keys after download.

    To use FDSK for downloading again, press and hold the base programming button for 5 seconds to restore factory settings.