--- title: "2.2.1 General setting" slug: "general-setting" updated: 2026-08-24T06:02:50Z published: 2026-08-24T06:02:50Z canonical: "knowledge.akuvox.com/general-setting" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 2.2.1 General setting ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-QFFGY77F.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-PXDAIX5Y.png) Figure 2.2.1 “General setting” Interface - **Device** **name****(****max****.40** **characters****)** Not applicable for HyPanel. - **Interface Language** Set the panel’s display language. Options: - Chinese, English, German, French, Portuguese, Russian, Spanish, Arabic, and Others. If your desired language is not listed, select “Others” and enter it in the Language name field. - **Language** **name** When choosing “Others” for the Interface Language, select your desired language from those supported by HyPanel and enter it here. > [!NOTE] > **NOTE:** > > If the entered language is not supported by HyPanel, English will be used by default. - **Send cycle of “In operation” telegram [1 to 240s, 0 = inactive]** Set the time interval when this device cycle send telegrams through the bus to indicate this module in normal operation. When set to “0”, the object “In operation” will not send a telegram. If the value is not “0”, the object “In operation” will send a telegram with a logic “1” to the bus at the preset time interval. Options: 0 ~ 240s, 0=inactive. To minimize the bus load as much as possible, the maximum time interval should be selected according to actual needs. - **Temperature** **display** **units** Set the display of temperature unit. Options: - Celsius (℃) - Fahrenheit (℉) - **Date** **and** **Time** **can** **be** **changed** **via** **bus** Support for bus modification of the date/time displayed on the HyPanel. Options: - No: Not supported - Yes: Supported. When selected, the "Date" and "Time" objects will be visible. Adjust them according to your requirements. - **Send** **day****/****night** **status** Not applicable for HyPanel. - **Proximity sensor response function** Enable/disable the proximity sensor response function. Options: - Disable - Enable - **Screen brightness can be changed via bus** Support for bus modification of brightness values. Options: - No - Yes - **Screen background setting** Not applicable for HyPanel. - **UI** **style** **for** **Multifunction** **page** Not applicable for HyPanel. - **Status** **indication** Not applicable for HyPanel. - **Screen** **saver** Not applicable for HyPanel. - **Delay** **time** **for** **screen** **saver** **[5..255]s** Not applicable for HyPanel. - **Delay time for turn off backlight [0..255]s** Not applicable for HyPanel. - **Password** **function** Not applicable for HyPanel. - **Delay time from function page back to home page when no operation[0.. 255,0=inactive] Seconds** Not applicable for HyPanel. - **Status** **object** **read** **request** **after** **restart** Set whether to send status request telegrams when the device starts up. Options: - Disable - Enable This parameter is applicable to feedback of switch status, dimming status, blind position, air quality display items, outdoor temperature detection, and energy monitoring in the function page. Once enabled, and upon device startup or bus power restoration, the device will send the following telegrams to the bus: - Telegram to read the status of switches or dimming brightness. - Telegram to read the blind position status. - Telegram to gather data on temperature, humidity, CO2, PM2.5, etc., detected by sensors. - Telegram to retrieve information on current, voltage, power, energy, etc., monitored by actuators.