How to Configure Arming Mode and Status
  • 01 Sep 2021
  • Dark
    Light
  • PDF

How to Configure Arming Mode and Status

  • Dark
    Light
  • PDF

Article Summary

The Arming function is used to connect various safety detection equipment to protect your home safety. It will ring when the safety detection equipment detects an abnormality, and can be linked to some related properties or mobile apps to let you know the safety information for the first time . Indoor monitor can connect to all sorts of sensorss, such as smoke detector, carbon dioxide concentration detector, temperature sensor, humidity sensor, infrared sensor. All the data produced by sensors is processed by indoor monitor, thus realizing integrated management.

Before Start

Applicable Device: All indoor monitor

How to Configure

Display Arming mode on the Home/More page
The Arming button is not displayed on indoor monitor by default.

Take home page as a example:

Go to Phone-Key/Display, choose Arming type for corresponding area.

50a71c061e7d7b9440c63871d5d02b9f_image2021-8-20_0-2-11_version=1&modificationDate=1629388932849&api=v2.png

Arming Mode
Tap Arming to enter the Arming interface.

Indoor monintor supports 4 modes, which are “Home mode,” “Night mode,” “Away mode” and “Disarm mode.”

On the device, go to Arming - Arming Mode. User can see all of the 8 zones and corresponding sensor types.

Adjust defence delay time. It means when user changes to the arming mode from other modes, there will be 90 seconds delay time.

Adjust alarm delay. It means when the sensor triggered, there will be 90 seconds delay time to announce the notification.

Press Save icon on the top right to save the modification.
73e2baf459148e7d45454588895ef0fb_image2021-8-20_0-3-49_version=1&modificationDate=1629389030164&api=v2.png

40081e2221452d9c7b8cd056353f39e8_image2021-8-20_0-4-22_version=1&modificationDate=1629389063735&api=v2.png

Disarm Code
Go to Arming - Disarm Code to enter the disarm code settings interface. Users can modify the disarm code here.

Enter the original disarm code ① first, and it is 0000 as default.

Enter the new disarm code ②.

Enter the new disarm code again ③ for confirming.

Press Save to save the modification.
3c95371e0ab5605efa14c8f121773d8e_image2021-8-20_0-6-56_version=1&modificationDate=1629389217592&api=v2.png

Alarm Log
Go to Arming - Alarm Log to enter the alarm log interface. Users can check the alarm log, including “location,” “zone,” “zone type” and “alarm time.”

Hold an alarm log ①, and it will show up delete prompt.

Press Select All ② and click Delete ③ to delete all alarm log.

Press Cancel ④ to cancel to deletion.
2f291b926962422f13d38ac67b6fae14_image2021-8-23_10-48-31_version=1&modificationDate=1629686912010&api=v2.png

Status
Go to Arming - Zone Status to enter the zone status interface. Users can check the status of zones, including “location,” “zone type,” “trigger mode” and “status.”
f904afc1876176478ab100437106271c_image2021-8-23_10-49-46_version=1&modificationDate=1629686987728&api=v2.png

Arming Setting
Go to Advance setting to configure it.
①Press this icon to enter zone settings interface.

②To choose a zone to set corresponding parameters. IT82 support up to 8 zones, you can connect up to 8 alarm sensors to indoor monitor.

③Configure the location of the alarm sensor, including Gate, Door, Bedroom, Guest room, Hall, Window, Balcony, Kitchen, Study and Bathroom.

④Configure the type of the alarm sensor, including Infrared, Drmagnet, Smoke, Gas, Urgency.

⑤Configure the trigger mode of the alarm sensor, including NC (Normal Close) and NO (Normal Open).

⑥Configure the status of alarm feature, including disabled, enabled and 24H.
48676d5b986d0a737f040182a6f76d8f_image2021-8-23_10-50-50_version=1&modificationDate=1629687053015&api=v2.png

1402b6335be0b826027300379a215f10_image2021-8-23_10-51-22_version=1&modificationDate=1629687082956&api=v2.png


Was this article helpful?