--- title: "Integration with Third Party Device" slug: "integration-with-third-party-device-18-1" status: "update" updated: 2026-10-20T10:00:12Z published: 2026-10-20T10:00:12Z canonical: "knowledge.akuvox.com/integration-with-third-party-device-18-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # Integration with Third Party Device ## Integration via Wiegand The access control terminal can be integrated with third-party devices via Wiegand. To set it up, go to **Device > Wiegand** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-PWTUY4LM.png) - **Wiegand Display Mode**: Select the Wiegand card code format from the provided options. - **Wiegand Card Reader Mode**: The transmission format should be identical between the access control terminal and the third-party device. It is automatically configured. - **Wiegand Transfer Mode**: - **Input**: The device serves as a receiver. - **Output**: The device serves as a sender. - **Wiegand Input Clear Time**: When the interval of entering passwords exceeds the time. All entered passwords will be cleared. - **Wiegand Input Data Order**: Set the Wiegand input data sequence between Normal and Reversed. If you select Reversed, then the input card number will be reversed. - **Wiegand Output Data Order:** Determine the sequence of the card number. - **Normal**: The card number is displayed as received. - **Reversed**: The order of the card number is reversed. - **ID Card Output Raw Bytes**: This option is available when Wiegand Transfer Mode is **Output**. Select the output bytes of ID cards between 3 bytes and 4 bytes. - **Wiegand Output CRC Enable**: It is enabled by default for Wiegand data inspection. Disabling it may lead to integration failure with third-party devices. - **Wiegand Out Verification**: This feature is for checking the card validity when Output mode is selected. This feature requires you to assign the card code to a user on the **Directory > User** interface. - **Card Entered Action**: This option is available when Wiegand Transfer Mode is **Output** and Wiegand Out Verification is disabled. You can enter an HTTP command sent to a third-party HTTP server to verify the validity of the card. Please refer to the HTTP formats: *http://{server ip}/validcard=$card_sn; http://{server ip}/invalidcard=$card_sn*. Replace {server ip} with the HTTP server IP. > [!NOTE] > Note > > Click [here](https://knowledge.akuvox.com/docs/configure-wiegand-in-door-phones) to see detailed configuration steps. ## Lift Control The device can be connected to the Akuvox lift controller for the lift control. You can summon the lift to go down to the ground floor when you are granted access through various types of access methods. To set up the lift control, go to **Device > Lift Control** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-PNGGGJRI.png) - **Lift Control List**: Select Akuvox for integration with the Akuvox lift controller. - **Server IP**: Enter the IP address of the Akuvox lift controller server. - **Port**: Enter the port of the Akuvox lift controller server. - **User Name**: Enter the user name of the lift controller for authentication. - **Password**: Enter the password of the lift controller for authentication. - **Floor NO. Parameter**: Enter the Floor number parameter provided by Akuvox. - **URL To Trigger Specific Floor**: Enter the URL for triggering a specific floor. - **URL To Trigger All Floors**: Enter the URL for triggering all floors. - **URL To Close All Floors**: Enter the URL used for closing all floors. ## Integration via HTTP API HTTP API is designed to achieve a network-based integration between the third-party device and the Akuvox intercom device. To set it up, go to **Setting > HTTP API** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/图片-MPYERFF2.png) - **HTTP API Enable**: Enable or disable the HTTP API function for third-party integration. If the function is disabled, any request to initiate the integration will be denied and return HTTP 403 forbidden status. - **Authorization Mode**: Select among the following options: None, Allowlist, Basic, Digest, and Token for authorization type, which will be explained in detail in the following chart. - **Username**: Enter the user name when **Basic** or **Digest** authorization mode is selected. The default username is admin. - **Password**: Enter the password when **Basic** or **Digest** authorization mode is selected. The default password is admin. - **1st IP-5th IP**: Enter the IP address of the third-party devices when the **Allowlist** authorization is selected for the integration. **Please refer to the following description for the Authentication mode:** | Authorization Mode | Description | | --- | --- | | None | No authentication is required. This mode is intended for testing only and is not recommended in production environments. | | Allowlist | Authenticates requests based on the source IP address. Add the IP address of the third-party device to the allowlist before sending requests. Recommended for trusted LAN environments. | | Basic | Authenticates requests using a username and password. The credentials must be Base64-encoded and included in the Authorization header. | | Digest | Authenticates requests using HTTP Digest authentication. Only the MD5 algorithm is supported. | | Token | Reserved for Akuvox internal development and testing. | ## Power Output Control The device can serve as a power supply for the external relays. Click [here](https://knowledge.akuvox.com/docs/devices-supporting-12v-power-output) to view the power output requirements and the [wiring example](https://knowledge.akuvox.com/docs/devices-supporting-12v-power-output#wiring). To set it up, go to **Access Control > Relay** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/图片-7GXQKQUG.png) - **12v Power Output Enabled**: - **Always**: The device can provide continuous power to the third-party device. - **Security Relay A**: The device can work with the security relay.