--- title: "1. Overview" slug: "o-2" updated: 2026-08-24T07:36:27Z published: 2026-08-24T07:36:27Z canonical: "knowledge.akuvox.com/o-2" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 1. Overview ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-GMA8YAFF.png) KXAC-G1DC4 The 4-gang universal dimming module (hereinafter referred to as the dimmer) provides four independent outputs, depending on the model. It can be connected to dimmable lighting loads such as incandescent lamps, halogen lamps, energy-saving lamps, and LED lamps. Via the KNX bus, the dimmer supports lighting on/off control, dimming, and scene control. In addition, it supports the KNX Security protocol. The dimmer is designed for DIN-rail mounting and is installed on a standard 35 mm DIN rail. Electrical connections are made using screw terminals. Bus connection is realized directly via KNX terminals, and no additional power supply is required apart from the KNX bus. The dimmer allows you to create various lighting scenes, such as movie watching, entertainment, dining, and relaxation. Each channel’s brightness can be set to any value between 1% and 100%. The transition time and dimming ramp can also be configured, ensuring smooth light changes that help extend lamp lifetime and reduce energy consumption. Physical address assignment and parameter configuration are performed using ETS engineering software (ETS5 or later) with the corresponding .knxprod file. During operation, attention must be paid to the connected load type and the technical characteristics of the dimmer. Mismatched load types or electrical characteristics may affect dimming performance. **Key features:** - Lighting on/off control, relative dimming, and absolute dimming - Status feedback for switching, brightness, and fault conditions, including short circuit, overvoltage, overtemperature, and power supply faults - Download, bus power-off, and bus power-on reset functions - Six dimming curves: linear, exponential, cubic, quadratic, logarithmic, root, plus a custom curve - Configurable leading-edge and trailing-edge dimming - Manual operation and output status indication - Central control function - Independent or parallel outputs (parallel mode increases load capacity) - Staircase lighting, flashing, timing functions, scenes, threshold control, forced operation, safety operation, and operation time counting - Logic functions: AND, OR, NOT, gate forwarding, threshold comparison, format conversion, gate function, delay function, and staircase function - KNX Secure support