--- title: "2.4.9 Page x - Ventilation system" slug: "page-x-ventilation-system" updated: 2026-08-20T09:05:53Z published: 2026-08-24T06:03:38Z canonical: "knowledge.akuvox.com/page-x-ventilation-system" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # 2.4.9 Page x - Ventilation system Parameter setting interface “Page x - Ventilation system”, as shown in Figure 2.4.9, mainly sets the parameters for the ventilation system controlling. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-2AJPU9WI.png) Figure 2.4.9-1 “Page x--Ventilation system” Interface ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-NG2SHXQE.png) Figure 2.4.9-2 “Page x--Ventilation system fan speed _1bit” Interface ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-PD31LRYE.png) Figure 2.4.9-3 “Page x--Ventilation system fan speed _1byte” Interface ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-VAEMR6P8.png) Figure 2.4.9-4 “Page x--Ventilation system” Interface - **Power on/off status after download** Set the power on/off status of the ventilation interface after the application is downloaded. Options: - Off - On - **Power on/off status after bus recovery** Set the power on/off status of the ventilation interface after the power is restored. Options: - On: When power is restored, the device will be in the powered-on state, and the interface will be operational. - Off: When power is restored, the device will be in the powered-off state. Other icons in the interface are not operational except for filter reset and on/off icons. - Before power off: Upon power restoration, the device returns to its status prior to power off. - **Default fan speed after power on** Set the initial fan speed when the ventilation is turned on. Options: - Low - Medium - High - **Data type of fan speed** Set the data type of the fan speed. Options: - 1bit - 1byte **The following parameters are visible when the “Data type of fan speed” is “1byte”, setting the status feedback values for each fan speed.** **- Output value for Fan speed off/low/medium/high** Define the values sent to switch to each fan speed. Options: 0..255s **- Status value for Fan speed off/low/medium/high** Set the status feedback values for each fan speed. The device updates the fan speed icon status based on the received feedback values. Options: 0..255 **The following parameters are visible when the “Data type of fan speed” is “1bit”.** **- Object value for Fan speed off/low/medium/high** Define the values sent to switch to each fan speed, simultaneously transmitted by three 1-bit objects. Options: - No.1=0, No.2=0, No.3=0 - No.1=1, No.2=0, No.3=0 - No.1=0, No.2=1, No.3=0 - No.1=1, No.2=1, No.3=0 - No.1=0, No.2=0, No.3=1 - No.1=1, No.2=0, No.3=1 - No.1=0, No.2=1, No.3=1 - No.1=1, No.2=1, No.3=1 **- Delay between fan speed switch [0 .. 100]*50ms** Set a delay in changing fan speeds, considering the technical specifications of the fan. Options: 0 .. 100 When switching fan speeds, the fan speed should first be turned off. Then, after a delay, the fan speed can be turned on before the telegram is sent to the bus. If the delay time is set to 0, the fan will switch directly to the next speed without turning off first. - **Heat Recovery function** Enable/disable the heat recovery function. Options: - Disable - Disable=0/Enable=1 - Disable=1/Enable=0 If the last two options are selected, the heat recovery function defaults to enable upon system power-on. If not enabled, the heat recovery function is uncontrollable. - **Filter timer counter** Not applicable for HyPanel. **- Evaluation time [100 .. 10000]*h** Not applicable for HyPanel. - **Auto. operation function** Enable the automatic control function of the ventilation system. Options: - Disable: The Auto mode is not available on the panel. - Enable - **Scene function** Enable the scene function of the ventilation system, with 5 scenes available for configuration. Options: - Disable - Enable **- x->Assign scene NO.[1.. 64,0=inactive], x=1~5** Set the scene number. Options: 0.. 64; 0 = inactive **- Fan level** Set the fan speed status of scene x. Options: - Off - Low - Medium - High **- Heat Recovery** Set the heat recovery status of scene x. Options: - Off - On This parameter is invalid when heat recovery is disabled. **- Voice command ID[120.. 129]** Not applicable for HyPanel.