--- title: "Relay Setting" slug: "relay-setting-2-wr01" updated: 2026-08-19T09:01:57Z published: 2026-08-26T06:09:12Z canonical: "knowledge.akuvox.com/relay-setting-2-wr01" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.akuvox.com/llms.txt > Use this file to discover all available pages before exploring further. # Relay Setting The device has two relay output interfaces for controlling external devices such as electric locks and access control systems. To set up the relay, go to **Access Control > Relay** interface. ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-FVZ5P10W.png) ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-SILJMHIO.png) - **Type**: Determine the interpretation of the Relay Status regarding the state of the door: - **Default State**: A “Low” status in the Relay Status field indicates that the door is closed, while “High” indicates that it is open. - **Invert State**: A “Low” status in the Relay Status field indicates an open door, while “High” indicates a closed one. - **Mode**: Specify the conditions for automatically resetting the relay status. - **Monostable**: The relay status resets automatically within the relay delay time after activation. - **Bistable**: The relay status resets upon triggering the relay again. - **Trigger Delay(Sec)**: Set the delay time before the relay triggers. For example, if set to 5 seconds, the relay activates 5 seconds after pressing the Unlock button. - **Hold Delay(Sec)**: Determine how long the relay stays activated. For example, if set to 5 seconds, the relay remains open for 5 seconds before closing. - **Action to Execute**: Check the action to be executed when the relay is triggered. - **HTTP**: When triggered, the HTTP message can be captured and displayed in the corresponding packets. To utilize this feature, enable the HTTP server and enter the message content in the designated box below. - **Email**: Send a screenshot to the preconfigured Email address. - **HTTP URL**: Enter the HTTP message if selecting HTTP as the action to execute. The format is http://HTTP server’s IP/Message content. - **Relay Name**: Assign a distinct name for identification purposes. - **Relay Status**: Indicate the states of the relay, which are normally open and closed. By default, it shows low for normally closed(NC) and high for Normally Open(NO). - **Door Sensor**: Specify which input interface is connected to a door sensor. - **Door Opened Alarm**: If enabled, when the door-opening time exceeds a limit, an alarm will be triggered. - **Door Opened Timeout**: The door-opening time limit. - **Break-in Alarm**: Activate an alarm when the door is forcibly or illegally opened. Only by checking off this option can the alarm be turned off once triggered. Click [here](https://knowledge.akuvox.com/docs/set-up-break-in-intrusion-alert) to learn more about this feature. - **Break-in Intrusion Execute Action**: If **Email** is checked, when the break-in intrusion occurs, a notification will be sent to the preconfigured email address. - **Access Method**: Check the method(s) to trigger the relay.