# Set up Break-in Intrusion Alert

The break-in intrusion feature makes door phones or access control terminals sound an alert when the door is forced open.

> [!NOTE]
> Note
> 
> - Make sure you have configured the input before enabling the break-in intrusion.
> - How to define the door is forced open?
>   - **Normal door opening**: The relay is triggered before the input is triggered, and the door is opened.
>   - **Abnormal door opening**: The input is triggered, and the door is opened before the relay is triggered.
> 
> Compatible models and versions(or higher):
> 
> S539, S538, S535, S532, X916, X915 V1/V2, X910, R29, A01/02/3, A08, and A095.
> 
> - A094: 92.30.10.130
> - E18: 18.30.10.236
> - E16V2: 216.30.10.208
> - E16V3: 416.30.11.206
> - E12V2: 312.30.10.237
> - R28V2: 228.30.10.218
> - X912: 912.30.11.107
> - R25: 25.30.10.117
> - A05V2: 205.30.11.114

This article takes R29 as an example.

## On the Device’s Web Interface

1. Use the device IP to log in to its web interface. The initial username and password are both admin.
2. Navigate to the **Access Control > Input** interface.
3. Enable the **Break-in Intrusion**.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-DZ8A1QPF.png)

1. Click **Submit** to save the settings.

When the door is forced open, an alarm will be triggered.

If you want to disarm the alarm, disable break-in intrusion on the web interface, or enter the disarm code.

The disarm code can be configured on the **System > Security > Disarm Setting** interface.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-PXNGDS6U.png)

> [!NOTE]
> Note
> 
> ONLY S539, S538, R29, S535, S532, X916, and X915 support disarming via PIN.

### A095 Break-in Intrusion Setup

A095 has 12 inputs, 8 of which can be connected to door sensors and trigger break-in intrusion alerts.

- If DPS(Door Position Switch) is used, enable it on the **Access Control > Door** interface.
- If AUX IN(Auxiliary Input) is used, enable it on the **Access Control > Auxiliary Input** interface.

Then, bind the input to the door.

1. Go to **Access Control > Door**.
2. Select the used input from the dropdown list.
3. Enable **Break-in intrusion**.
4. Choose the **Break-in Intrusion Trigger Door**. AUX OUT 1 - 4 corresponds to the 4 auxiliary outputs that can be connected to an external siren.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-4NL2CS7V.png)

1. Click Submit.

> [!WARNING]
> Tip
> 
> Click [here](/v1/docs/configure-a095-disarm-settings) to view how to disarm A095.

## On the Smart Access Cloud

If the device is deployed on the cloud, you can set up the break-in alarm feature on the cloud.

Both installers and project managers can set up this feature for devices in new commercial projects(created after Oct.15, 2024).

> [!NOTE]
> Compatible models and versions(or higher):
> 
> | Model | Version | Model | Version |
> | --- | --- | --- | --- |
> | R29 | 29.30.10.404 | R28 V2 | 228.30.10.231 |
> | R25 | 25.30.10.117 | R20 | 320.30.11.30 |
> | X915 V2 | 2915.30.10.420 | X912 | 912.30.11.107 |
> | X910 | 2910.30.11.28 | E16 V2 | 216.30.10.208 |
> | A08 | 108.30.11.8 | A01/A02 | 101.30.10.206 |
> | A03 | 103.30.10.204 | A094 | 92.30.10.205 |
> | A095 | 95.30.10.110 | E12 V2 | 312.30.11.18 |
> | S539 | 539.30.10.507 | X916 | 916.30.10.508 |
> | S535 | 535.30.11.8 | S538 | 538.30.10.705 |
> | A05 V2 | 205.30.11.114 | E16 V3 | 416.30.11.206 |

Take an installer account as an example.

1. Log in to the cloud system with your account.
2. Click ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-7EAZZUGD.png) of the target commercial project.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-PERP3YV2.png)

1. Click **Devices** on the left column.
2. Click ![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-9TP2VMU3.png) of the target device.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-QVH0ME4D.png)

1. Select **Door** and find the **Door Status** part.
2. Select the input that is connected to the door sensor.
3. Enable the break-in alarm feature.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-L1MU5VTD.png)

1. Click Submit.