# Set up Emergency Scenarios

The Emergency Scenario feature allows property managers/project managers to configure automatic actions when an emergency event is triggered.

An Emergency Scenario consists of a trigger source and one or more actions. When the trigger condition is met, the configured actions are executed automatically to improve emergency response efficiency.

Emergency Scenarios support:

- Egress: Automatically unlock configured doors for evacuation.
- Lockdown: Automatically lock configured doors to restrict access.
- Emergency notifications to users.
- EC33 elevator floor release (if configured).
- Multiple emergency scenarios for different areas.

You can create multiple scenarios, each with its own door group and trigger source — for example, a separate Egress scenario for each building on a site, or a Lockdown scenario that only covers a restricted wing.

> [!NOTE]
> Upgrading from Emergency Settings
> 
> If your project previously used Emergency Settings, it is automatically converted into a scenario named **Egress**, using your existing configuration and tagged **Auto-Converted**. You can review or adjust it on the Emergency Scenario page after upgrading.

## Supported Scenarios

This feature applies to:

- Community Projects
- Commercial Projects

Configuration logic is the same. Differences are limited to:

- Compatible models & firmware
- Account role (Property Manager / Project Manager)

## Compatible Models and Minimum Versions

### Door Phones & Access Control Devices

Firmware requirements now come in two tiers, since older firmware can still trigger a scenario but can't report which input caused it:

- **Alarm-Only (legacy firmware)** — device can trigger a scenario, but only reports that an alarm occurred, not the specific input. Not usable as a distinct **Trigger Source** when a project has multiple scenarios.
- **Full Trigger Source Support** — device reports which input was triggered, enabling multiple scenarios each bound to a different input.

**Full Trigger Source Support**

| Model | Minimum Version | Model | Minimum Version |
| --- | --- | --- | --- |
| X915V2 | 2915.30.10.811 | A095 | 95.30.11.104 |
| R20V5* | 320.30.12.103 | A01/A02 | 101.30.11.204 |

R20V5*: R20 firmware version 320.30.12.104 does not support the full feature.

**Alarm-Only**

| **Model** | **Community Min Version** | **Commercial Min Version** |
| --- | --- | --- |
| S539 | 539.30.1.105 | 539.30.10.226 |
| S538 | 538.30.10.705 | 538.30.10.705 |
| S535 | 535.30.10.233 | 535.30.10.233 |
| S532 | 532.30.10.117 | 532.30.10.211 |
| X915 V2 | 2915.30.10.8 | 2915.30.10.211 |
| X916 | 916.30.10.116 | 916.30.10.222 |
| X912 | 912.30.10.108 | 912.30.11.49 |
| X910 | 2910.30.11.28 | 2910.30.10.240 |
| R29 | 29.30.3.214 | 29.30.10.314 |
| R28 V2 | 228.30.10.135 | 228.30.10.218 |
| R25 | 25.30.10.117 | 25.30.10.117 |
| R20 V5.0 | 320.30.10.125 | 320.30.10.125 |
| E18 | 18.30.10.236 | 18.30.10.236 |
| E16 V2 | 216.30.0.67 | 216.30.10.208 |
| E16 V3 | 416.30.11.206 | 416.30.11.206 |
| E12 | 312.30.2.105 | 312.30.11.18 |
| EC33 | 33.30.1.2 | 33.30.1.107 |
| A01/A02 | 101.30.10.108 | 101.30.10.108 |
| A03 | 103.30.10.111 | 103.30.10.111 |
| A05V2 | 205.30.10.119 | 205.30.10.119 |
| A08 | 108.30.10.108 | 108.30.10.108 |
| A094 | 92.30.10.17 | 92.30.10.17 |
| A095 | 95.30.10.110 | 95.30.10.110 |
| E13 | 13.30.10.16 |  |

### Indoor Monitors

| Model | Minimum Version |
| --- | --- |
| C313 V2.0: 212.30.13.25 | S563: 563.30.13.404 |
| C313 V3.0: 313.30.14.9 | S565: 565.30.10.210 |
| C316: 316.30.13.302 | S567: 567.30.13.305 |
| C319: 119.30.13.602 | X937: 937.30.14.209 |
| S562: 562.30.14.204 | X933: 933.30.14.403 |
| IT88: 88.30.14.603 | S562-2: 5622.30.15.18 |
| C313V2-2: 212.30.13.25 |  |

### SmartPlus App

| System | Minimum Version |
| --- | --- |
| Android | 7.50.0003 |
| iOS | 7.50.3 |

## Step 1: Create an Emergency Scenario

1. Log in to the cloud platform with your PM account.
2. Click **Settings** **> Emergency Scenario > New**.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-RY0OU9HE.png)

1. Define the scenario name.
2. Select the scenario type: **Egress** or **Lockdown**. Currently, only commercial projects support the **Lockdown** type.
3. Select the **Door Group** this scenario controls.
4. Select a **Trigger Source** — the device and input that will automatically activate this scenario.
5. Configure the remaining options for the selected type (see table below).

| Field | Egress | Lockdown |
| --- | --- | --- |
| Auto-Activate Scenario on Input Trigger | **On**: Open all configured doors automatically when the scenario is triggered. **Off**: Click **Emergency Scenario** near the top of any interface to activate or deactivate a scenario manually. |
| Auto Unlock All Floors When Scenario Activated | It works with EC33 elevator control. If turned on, all floors controlled by EC33 will be released upon the scenario trigger. | Not available |
| Send Emergency Notifications on Scenario Activation | If turned on, users’ SmartPlus Apps and indoor monitors will receive a notification. | Not available |
| Auto-Clear | Available when **Auto-Activate Scenario on Input Trigger** is turned on. When it is enabled, the emergency scenario is automatically cleared once the trigger input signal is restored. Affected doors and floors return to their regular schedules. |

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-678T73UH.png)

1. Click Submit.

## Step 2: Enable the Input (Non-Upgraded Devices Only)

This step is only required if the device you selected as the Trigger Source in Step 1 **has not been updated** to support Emergency Scenario.

Updated devices are fully configured by Step 1 — skip this step for those.

1. Navigate to the device IP in a browser. Log in with the username and password(admin/admin by default).
2. Go to **System > Security**. Check the input(s) that are connected to the alarm sensor.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-G756POVV.png)

1. Click Submit.
2. Make sure the input is enabled on the **Access Control > Input** interface.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-EPZODKSF.png)

## Step 3: Verification

While one or more scenarios are active, a red banner appears at the top of the platform listing the active scenarios.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-Q7K47OIC.png)

The indoor monitor will display a prompt and sound an alarm for 30 seconds.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/screenshots (64)(1).png)

The SmartPlus App will receive the notification.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-1785811995623.png)

## Manual Control

You can also activate or deactivate a scenario manually from the **Emergency Scenario** page, without waiting for the trigger source.

![](https://cdn.document360.io/f09a6106-e976-455e-b2d0-3d88b5385960/Images/Documentation/image-EEZHHR0R.png)