System Log

System logs can be used for debugging purposes.

You can set up the function on the web Upgrade > Advanced > System Log interface.
image.png

Parameter Set-up:

  • Log Level: select log levels from 1 to 7 levels. You will be instructed by Akuvox technical staff about the specific log level to be entered for debugging purposes. The default log level is 3, the higher level is 5, and the more complete log is 7.
  • Export Log: click the Export tab to export a temporary debug log file to a local PC.
  • Remote System Server: enter the remote server address to receive the device log. And the remote server address will be provided by Akuvox technical support.
  • Remote System Port: enter the remote system server port for the data transmission.

Remote Debug Server

When the device is having a problem, you can use the remote debug server to access the device log remotely for debugging purposes.


On the web, navigate to Upgrade > Advanced > Remote Debug Server.
image.png

PCAP

PCAP is used to capture the data package going in and out of the devices for debugging and troubleshooting purposes.

You can set up the PCAP on the device web Upgrade > Advanced > PCAP interface properly before using it.
image.png

Parameter Set-up:

  • Specific Port: select the specific ports from 1-65535 so that only the data packet from the specific port can be captured. You can leave the field blank by default.
  • PCAP: click the Start tab and Stop tab to capture a certain range of data packets before clicking the Export tab to export the data packets to your Local PC.
  • PCAP Auto Refresh: select Enable or Disable to turn on or turn off the PCAP auto fresh function. If you set it as Enable then the PCAP will continue to capture data packets even after the data packets reached their 1M maximum in capacity. If you set it as Disable the PCAP will stop data packet capturing when the data packet captured reached the maximum capturing capacity of 1MB.
  • New PCAP: click Start to capture a bigger data package.