LED Fill Light
LED fill light is mainly designed to reinforce the light at night or in a dark environment.
Navigate to the web Intercom > LED Setting > LED Fill Light interface.
Parameter Set-up:
- Mode: Auto enables the LED light to be turned on automatically. Schedule turns on the LED according to the time schedule.
- Min/Max Photoresistor: set the minimum and maximum photoresistor value based on the current actual photo-resistor value detected to control the ON-OFF of the LED light. You can set the maximum photoresistor value for the IR LED to be turned on and the minimum value for it to be turned off. The minimum and maximum photoresistor value are from 0 to 1800 respectively.
LED Display Status
LED display adjustment is used to indicate the light changes of the call button in 5 statuses: normal (idle), offline, calling, talking, and receiving a call. The LED status allows users to verify the current mode of the device.
To set it up on the web Intercom > LED Setting > LED Status interface.
The default LED Display Status:
LED Status | Description | ||
---|---|---|---|
Blue | Always on | Normal status | |
Flashing | Calling | ||
Red | Flashing | Network is unavailable | |
Green | Always on | Talking on a call | |
Flashing | Receiving a call | ||
Pink | Flashing | Upgrading |
Parameters Set-up:
- State: there are five states: Normal, Offline, Calling, Talking and Receiving.
- LED Color: it can support three colors: Red, Green, Blue.
- LED Display Mode: the different blink frequencies.
The Status and Color of item cannot be changed.
The LED of upgrading mode cannot be adjusted.
Set up LED Display from HTTP URL
You can enter the HTTP URL in the browser to manage the LED color and frequency.
Navigate to the web Intercom > LED Setting > LED Control to enable the function.
The HTTP URL format is: http://PhoneIP/fcgi/do?action=LedAction&State=1&Color=1&Mode=2500
- Status: 1=Idle; 2=OffLine; 3=Calling; 4=Talking; 5=Receiving; Color: 1=Green; 2=Blue; 3=Red; Mode: 0=Always On; 1=Always Off; 500/1000/1500/2000/25000/3000
LED Setting on Card Reader Area
You can enable or disable the LED lighting on the card reader area as needed on the web interface. Meanwhile, if you do not want to have the LED light on the card reader area stay on, you can also set the timing for the exact time span during which the LED light can be disabled in order to reduce electrical power consumption.
Navigate to the web Intercom > LED Setting > LED Control interface.
Parameters Set-up:
- Time (H): the time span for the LED lighting to be valid. If the time span is set from 8-0 (Sart time- End time), it means LED light will stay on during the time span from 8:00 am to 12:00 pm during one day (24 hours).
LED Setting on Keypad
You can enable or disable the LED lighting on the keypad area as needed on the web interface. Meanwhile, if you do not want to have the LED light on the card reader area stay on, you can also set the timing for the exact time span during which the LED light can be disabled in order to reduce electrical power consumption.
Navigate to the web Intercom > LED Setting > LED Control interface.
- Time (H): the time span for the LED lighting to be valid. If the time span is set from 8-0 (Sart time- End time), it means LED light will stay on during the time span from 8:00 am to 12:00 pm during one day (24 hours).