Akuvox door phones are compatible with different types of electronic locks, including powerbold locks, electric strikes, and electromagnetic locks. This article gives a brief introduction on the locks,  guides you on selecting the door lock, and teaches you to connect them to the door phone relay.

Applicable models:

No

Model

1S539

2

X916S

3

X915S

5

R29C

6

R29C-L

7

R29C-B

8

R28A

9

R27A

10

R20K

11

R20B

12

R20A

13

E16C

14E18C

15

E11R

16

E21V

17

E21A

18

A05S

Door Locks Introduction 

Electronic door lock mainly has following three types:

PowerBold Locks

This lock can be locked with power (NC, normally closed) or open with power (NO, normally open). When it is set to be NC, the lock can be opened when it is open-circuited. 

_scroll_external/attachments/image2021-9-14_10-39-22-4792e9d4bd7e3d5318395a420654059b9707a1c50112f1f198b47dcd5f444193.png_scroll_external/attachments/image2021-9-14_10-39-30-d0fa722cbe72bc865ff03373135577334337592d8ed7b7abd567aa52a24edcd9.png

Electric Strike

Likewise, the electric strike can be opened when it is short-circuited.

_scroll_external/attachments/image2021-9-14_10-40-19-4cf762a23934244831b4352311b5eb1bca1d01b2174e5a194cb537317aa3bc54.png

Electromagnetic Locks

The electromagnetic lock is locked when the power is on, which means it can be opened when it is open-circuited.

_scroll_external/attachments/image2021-9-14_10-40-52-3f4047ac67939208305e12e2821a34b339616fcc51f00b1133dae4509956540d.png

How to Select the Door Lock

You can select the door lock based on the following two purposes.

A.  Fail-safe: when the fail-safe mechanism is applied, the lock will stay locked when the power is on( close-circuited, with current on) and unlocked when it is open-circuited (with current off). Therefore, the fail-safe mechanism allows you not to be locked inside when a sudden power cut occurs. All the above three types of door locks are applicable to the fail-safe.

B.  Fail-secure: when the fail-safe mechanism is applied, the lock will stay locked when the power is off (open-circuited, with current off), and unlocked when it is short-circuited (with current on). This means the fail-secure mechanism can keep the door lock stay locked when a sudden power cut occurs. Both the PowerBold Lock and electrical strike are applicable to the fail-secure.

Note
  • Select the NC lock for fail-safe application, while select NO lock for fail-security.  

How to Wire the Door Lock to Door Phone Relay

You can watch the following two videos for reference.

Note
  • The power supply to all these locks must be 12V DC.

Electromagnetic Door Locks Wiring