Set up Break-in Intrusion Alert

Prev Next

The break-in intrusion feature makes door phones or access control terminals sound an alert when the door is forced open.

Note

  • Make sure you have configured the input before enabling the break-in intrusion.

  • How to define the door is forced open?

    • Normal door opening: The relay is triggered before the input is triggered and the door is opened.

    • Abnormal door opening: The input is triggered and the door is opened before the relay is triggered.

This article takes R29 as an example.

On the Device’s Web Interface

Compatible models and versions(or higher):

S539, S532, X916, X915 V1/V2, X910, R29, A01/02/3, A08, and A095.

  • A094: 92.30.10.130

  • E18: 18.30.10.236

  • E16V2: 216.30.10.208

  • E12V2: 312.30.10.237

  • R28V2: 228.30.10.218

  • X912: 912.30.11.107

  • R25: 25.30.10.117

  1. Use the device IP to log in to its web interface. The initial username and password are both admin.

  2. Navigate to the Access Control > Input interface.

  3. Enable the Break-in Intrusion.

  1. Click Submit to save the settings.

When the door is forced open, an alarm will be triggered.

If you want to disarm the alarm, disable break-in intrusion on the web interface, or enter the disarm code.

The disarm code can be configured on the System > Security > Disarm Setting interface.

A095 Break-in Intrusion Setup

A095 has 12 inputs, 8 of which can be connected to door sensors and trigger break-in intrusion alerts.

  • If DPS(Door Position Switch) is used, go to the Access Control > Door interface for configuration.

  • If AUX IN(Auxiliary Input) is used, go to the Access Control > Auxiliary Input interface for configuration.

  1. Select the door that triggers the alarm in the Break-in intrusion drop-down list.

  2. Choose the Break-in Intrusion Trigger Door. AUX OUT 1 - 4 corresponds to the 4 auxiliary outputs that can be connected to door locks.

DPS

AUX IN

Tip

Click here to view how to disarm A095.

On the Smart Access Cloud

If the device is deployed on the cloud, you can set up the break-in alarm feature on the cloud.

Both installers and project managers can set up this feature for devices in new commercial projects(created after Oct.15, 2024).

Compatible models and versions(or higher):

Model

Version

Model

Version

R29

29.30.10.404

R28 V2

228.30.10.231

R25

25.30.10.117

R20

320.30.11.30

X915 V2

2915.30.10.420

X912

912.30.11.107

X910

2910.30.11.28

E16 V2

216.30.10.208

A08

108.30.11.8

A01/A02

101.30.10.206

A03

103.30.10.204

A094

92.30.10.205

A095

95.30.10.110

E12 V2

312.30.11.18

S539

539.30.10.507

Take an installer account as an example.

  1. Log in to the cloud system with your account.

  2. Click of the target commercial project.

  1. Click Devices on the left column.

  2. Click of the target device.

  1. Select Door and find the Door Status part.

  2. Select the input that is connected to the door sensor.

  3. Enable the break-in alarm feature.

  1. Click Submit.