Security

Prev Next

Tamper Alarm

The tamper alarm function prevents anyone from removing the device without permission. Akuvox devices support two types of tamper proof: gravity detection and button status detection.

Click here to view which type is supported by the device and learn the function details.

Set it up on the System > Security > Tamper Alarm interface. Click Disarm to clear the alarm.

Disarm Setting

You can set the disarm code on the web System > Security > Disarm Setting interface. A13C only supports disarm card code.

  • PIN Code: Tap X, then ✔ on the device, and enter the PIN to disarm.

  • Card Code: Swipe the card to disarm. Click Obtain while placing the card on the device to fill in the card code automatically.

Security Notification

A security notification informs users or security personnel of any breach or threat that the device detects. For example, if the device detects something unusual, the system sends a notification to users or security through email, phone calls, or other methods.

To set up security notifications, go to Setting > Action interface.

Email Notification

Set up email notifications to receive screenshots of unusual motion from the device.

Click here to view how to set this feature up.

Set it up in the Email Notification section.

  • SMTP Server Address: The SMTP server address of the sender.

  • Port: The port value of the SMTP server address.

  • SMTP Username: The SMTP username is usually the same as the sender's email address.

  • SMTP Password: The password of the SMTP service is the same as the sender's email address.

Action URL

You can use the device to send specific HTTP URL commands to the HTTP server for certain actions. These actions will be triggered when the relay status, input status, PIN code, or RF card access changes.

Akuvox Action URL:

Event

Parameter format

Example

Relay Triggered

$relay1status

Http://server ip/ relaytrigger=$relay1status

Relay Closed

$relay1status

Http://server ip/relayclose=$relay1status

Input Triggered

$input1status

Http://server ip/inputtrigger=$input1status

InputA-C corresponds to Input1-3.

Input Closed

$input1status

Http://server ip/inputclose=$input1status

InputA-C corresponds to Input1-3.

Valid Code Entered(Only for A13S)

$code

Http://server ip/validcode=$code

Invalid Code Entered(Only for A13S)

$code

Http://server ip/invalidcode=$code

Valid Card Entered

$card_sn

Http://server ip/validcard=$card_sn

Invalid Card Entered

$card_sn

Http://server ip/invalidcard=$card_sn

Tamper Alarm

$alarmstatus

Http://server ip/tampertri=$alarmstatus

Alarm Door Opened Timeout

—

http://server ip/NotifyAlarm&AlarmMsg={message content}&FromName={device name}&AlarmCode=1

For example: http://192.168.16.118/help.xml? mac=$mac:ip=$ip:model=$model:firmware=$firmware:card_sn=$card_sn

To set it up, go to the Setting > Action URL interface.

Anti-passback Mode

This anti-passback mode restricts users from entering the door by following others.

Set it up on the Directory > User interface.

  • Mode: Select Entry or Exit to enable the feature. For example, if the user follows someone else through the door, the next time he/she cannot swipe his/her card to pass through the Entry/Exit door.

Real-Time Monitoring

This feature displays the door status when the device is connected to the SmartPlus Cloud. Property managers and end users can check the door status, respectively, on the SmartPlus Property Manager platform and SmartPlus App. You need to specify the relay(s) or input(s) that apply this feature.

Click here to see the detailed configuration.

To set it up, go to System > Security > Real-Time Monitoring interface.

  • Apply Setting To:

    • None: Not display door status.

    • Input: The door is opened by triggering input.

    • Relay: The door is opened by triggering the relay.

Emergency Action

This feature works with Akuvox SmartPlus Cloud. It keeps the door open when an emergency happens. You need to specify the Input that applies the feature.

Click here to view the detailed configuration of this feature.

To set it up, go to System > Security > Emergency Action interface. Select the Input(s) to be triggered.

Web Interface Automatic Log-out

You can set up the web interface's automatic log-out timing, requiring re-login by entering the username and the password for security purposes or for the convenience of operation.

To set it up, go to System > Security > Session Time Out interface.

High Security Mode

High security mode is designed to enhance the security. It employs encryption across various facets, including the communication process, door opening commands, password storage methods, and more.

Enable it on the System > Security > High Security Mode interface.

Important Notes

1. The High Security mode is off by default when you upgrade the device from a version without the mode to one with it. But if you reset the device to its factory settings, the mode is on by default.

2. This mode makes the old version tools incompatible. You need to upgrade them to the following versions or higher to use them.

  • PC Manager: 1.2.0.0

  • IP Scanner: 2.2.0.0

  • Upgrade Tool: 4.1.0.0

  • SDMC: 6.0.0.34

3. The supported HTTP format for relay triggering varies depending on whether high secure mode is enabled or disabled.

If the mode is on, the device only accepts the new HTTP formats below for door opening.

  • http://username:password@deviceIP/fcgi/OpenDoor?action=OpenDoor&DoorNum=1

  • http://deviceIP/fcgi/OpenDoor?action=OpenDoor&DoorNum=1

If the mode is off, the device can use both the new formats above and the old format below:

  • http://deviceIP/fcgi/do?action=OpenDoor&UserName=username&Password=password&DoorNum=1

4. It is not allowed to import/export configuration files in tgz. format between a device with the high security mode and another one without it. For assistance with file transfer, please contact Akuvox technical support.