Local Relay

Un relé local es una unidad externa que está físicamente cerca y directamente conectada al dispositivo de intercomunicación. Permite al sistema de interfono activar acciones, como abrir una puerta, según la entrada o autorización del usuario.

You can configure the relay switch and DTMF for door access on the Access Control > Relay interface.

  • Relay Type: Determine the interpretation of the Relay Status regarding the state of the door:

    • Default Status: A “Low” status in the Relay Status field indicates that the door is closed, while “High” indicates that it is open.

    • Invert Status: A “Low” status in the Relay Status field indicates an open door, while “High” indicates a closed one.

  • Mode: Specify the conditions for automatically resetting the relay status.

    • Monostable: The relay status resets automatically within the relay delay time after activation.

    • Bistable: The relay status resets upon triggering the relay again.

  • Trigger Delay (Sec): Set the delay time before the relay triggers. For example, if set to 5 seconds, the relay activates 5 seconds after pressing the Unlock button.

  • Hold Delay (Sec): Determine how long the relay stays activated. For example, if set to 5 seconds, the relay remains open for 5 seconds before closing.

  • Action to Execute: Check the action to be executed when the relay is triggered.

    • HTTP: When triggered, the HTTP message can be captured and displayed in the corresponding packets. To utilize this feature, enable the HTTP server and enter the message content in the designated box below.

    • Email: Send a screenshot to the preconfigured Email address.

  • HTTP URL: Enter the HTTP message if selecting HTTP as the action to execute. The format is http://HTTP server’s IP/Message content.

  • Relay Status: Indicate the states of the relay, which are normally open and closed. By default, it shows low for normally closed(NC) and high for Normally Open(NO).

  • Relay Name: Assign a distinct name for identification purposes.

  • Door Sensor: Specify which input interface is connected to a door sensor.

  • Door Opened Alarm: If enabled, when the door-opening time exceeds a limit, an alarm will be triggered.

    • Door Opened Timeout: The door-opening time limit.

  • Break-in Alarm: Activate an alarm when the door is forcibly or illegally opened. Click here to learn more about this feature.

  • Break-in Alarm Execute Action: If Email is checked, when the break-in intrusion occurs, a notification will be sent to the preconfigured email address.

  • Test: Click Test to trigger the relay manually.

Security Relay

El Relé de Seguridad, conocido como Akuvox SR01, es un producto diseñado para reforzar la seguridad de acceso evitando intentos de entrada forzada no autorizados. Instalado dentro de la puerta, regula directamente el mecanismo de apertura de la puerta, asegurando que la puerta permanezca segura incluso en caso de daño en el dispositivo.

Haz clic aquí para ver cómo configurar el relé de seguridad.

To set up the security relay, go to Access Control > Relay > Security Relay interface.

  • Connect Type: The connection type is RS485 by default. To use SR01, the RS485 mode should be set to Security Relay on the Access Control > RS485 interface.

  • Trigger Delay(Sec): Set the delay time before the relay triggers. For example, if set to 5 seconds, the relay activates 5 seconds after pressing the Unlock button.

  • Hold Delay(Sec): Determine how long the relay stays activated. For example, if set to 5 seconds, the relay remains open for 5 seconds before closing.

  • Relay Name: Name the security relay. The name can be displayed in the door-opening logs. When connecting to the SmartPlus Cloud, the Cloud server will automatically assign the relay name.

  • Test: Click to send the signal to the SR01. When the device and SR01 are pairing, click Test to finish the matching.

Web Relay

Un relé web tiene un servidor web integrado y puede ser controlado a través de Internet o de una red local. El dispositivo puede usar un relé web para controlar un relé local o un relé remoto en otro lugar de la red.

Haz clic aquí para ver cómo configurar un relé web.

To set it up, go to Access Control > Web Relay interface.

  • Type: Determine the type of relay activated when employing door access methods for entry.

    • Disabled: Only activate the local relay.

    • Web Relay: Only activate the web relay.

    • Local Relay + Web Relay: Activate both the local relay and web relay. Typically, the local relay is triggered first, followed by the web relay.

  • IP Address: The web relay IP address provided by the web relay manufacturer.

  • Username: The username provided by the web relay manufacturer.

  • Password: The manufacturer-provided authentication key for the web relay. Authentication occurs via HTTP. Leaving the Password field blank indicates non-use of HTTP authentication. You can define the password using HTTP GET in the Web Relay Action field.

  • Web Relay Action: Configure the actions to be performed by the web relay upon triggering. Enter the manufacturer-provided URLs for various actions, with up to 50 commands.

NOTE

If the URL includes full HTTP content (e.g., http://admin:admin@192.168.1.2/state.xml?relayState=2), it doesn't rely on the IP address that you entered above. However, if the URL is simpler (e.g., state.xml?relayState=2), the relay uses the entered IP address.

Relay Keep Active While Card Present

Enable this feature to keep the relay triggered continuously while a valid card stays within its reader's detection range. The relay will deactivate automatically when the card is moved away.

Note

  • Upon detecting a valid card, the device generates a Card Present Access Log and activates the relay.

  • While continuously reading the card, the relay remains active. No additional Access Logs are generated.

  • Upon detecting the card leaving the reading area, the device generates a Card Removed Access Log.

Set up this feature on the Access Control > Relay > Relay Keep Active While Card Present interface.

  • Enabled: Turn on/off the feature.

  • Open Relay: Check the relay to be triggered.

  • Hold Delay(Sec): The time the relay remains active after the card is removed.